Recovering tissue volumes from a single bioimpedance spectrum: an error analysis from phantoms and simulation
Journal of Electrical Bioimpedance · 01.01.2026 · 17 (1) · 198-213
DOI: 10.2478/joeb-2026-0019 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Electrical Bioimpedance, online erschienen am 09.11.2026. Verfasst von Gautam Anand und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Electrical and Electronic Engineering, School of Engineering Computer and Mathematical Sciences, Auckland University of Technology, Auc…. Die Arbeit nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Bioelectrical impedance analysis (BIA) estimates body composition through equations calibrated on reference populations, and its error for an individual is typically about ±8 percentage points of body fat. A physics-based estimate from a single spectrum would remove this dependence on calibration, although the errors that limit such an estimate have not yet been quantified against a known truth. This work quantifies these errors with three-layer phantoms of known composition, a finite element (FE) model verified against Ansys Maxwell, and simulations with phantom and tissue properties over 1–251 kHz. Without fitted parameters, the FE model predicted the impedance of two cylindrical phantoms measured with spot electrodes to within 1.1% and 6%. With the measurement scale fixed from the phantom dimensions, the fat fraction of all three phantoms was recovered to within 3 percentage points. The fat-free and water fractions, whose material spectra were very similar, were poorly separated. Without a known scale, recovery failed for the two gelatine phantoms. The fat fraction of an agar phantom with a more distinct fat spectrum, however, was still recovered to within 1 percentage point. In simulations, tissue spectra allowed recovery without a known scale, with typical errors of 3–5 percentage points, but only when the tissue properties were known exactly. A 10–20% spread in these properties raised the typical errors to 7–15 percentage points, and an extension of the band to 2 MHz did not reduce them. An uncorrected setup error, measured as 120 pF with a 14 ns delay, reduced recovery of the tissue set from 97% to 58%. Physics-based recovery therefore requires either a known scale, together with a validated electrode model and a corrected setup, or material spectra distinct enough to fix the scale. These findings define the requirements for phantoms intended to test such methods.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Electrical and Electronic Engineering, School of Engineering Computer and Mathematical Sciences, Auckland University of Technology, Auckland, New Zealand.
- AUT Institute of Biomedical Technologies, Auckland University of Technology, Auckland, New Zealand.
Zitieren
APA
Anand, G., Kalra, A., Ballav, A., & Mani, R. S. (2026). Recovering tissue volumes from a single bioimpedance spectrum: an error analysis from phantoms and simulation. Journal of Electrical Bioimpedance, 17(1), 198-213. https://doi.org/10.2478/joeb-2026-0019
Vancouver
Anand G, Kalra A, Ballav A, Mani RS. Recovering tissue volumes from a single bioimpedance spectrum: an error analysis from phantoms and simulation. Journal of Electrical Bioimpedance. 2026;17(1):198-213. doi:10.2478/joeb-2026-0019
BibTeX
@article{Anand2026,
author = {Anand, Gautam and Kalra, Anubha and Ballav, Arunima and Mani, Rebacca Sara},
title = {Recovering tissue volumes from a single bioimpedance spectrum: an error analysis from phantoms and simulation},
journal = {Journal of Electrical Bioimpedance},
year = {2026},
volume = {17},
number = {1},
pages = {198--213},
doi = {10.2478/joeb-2026-0019}
}
EUVIMED