EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Finite element modeling of human thorax for electrical bioimpedance based monitoring of pulmonary fluid accumulation

Frijia Mortuza, Md Shahriar Kabir, Md Zaman Molla, Md Ibrahim Al Imran, Muhammad Abdul Kadir

Journal of Electrical Bioimpedance · 01.01.2026 · 17 (1) · 4-13

DOI: 10.2478/joeb-2026-0002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrical Bioimpedance, online erschienen am 15.03.2026. Verfasst von Frijia Mortuza und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Biomedical Physics and Technology, University of Dhaka, Dhaka, 1000, Bangladesh. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Monitoring fluid accumulation in the lungs is critical in conditions such as pulmonary edema and pneumonia. Current diagnostic modalities, including auscultation, chest X-ray, computed tomography, magnetic resonance imaging, and ultrasonography, either involve ionizing radiation or are not suitable for continuous long-term monitoring. This study investigated the feasibility of a non-invasive, non-ionizing electrical impedance–based approach for continuous assessment of pulmonary fluid accumulation using computational modeling. Firstly, CT images of human subjects were used to build a simplified thorax model. Different parts of human thorax including airways, left and right lungs, and soft tissue were segmented using a segmentation software Materialise Mimics ® and imported into COMSOL Multiphysics ® for finite element analysis. Tetrapolar transfer impedance was computed at multiple vertical electrode positions under baseline (air-filled lung) and fluid-accumulation conditions. The results demonstrated a measurable reduction in impedance in the presence of fluid, particularly at electrode levels corresponding to the fluid-filled lower lobes. A linear relationship between impedance and fluid volume was observed (R 2 = 0.9972 for the left lung and R 2 = 0.9998 for the right lung), with sensitivities of −466.74 mΩ/100 mL and −754.75 mΩ/100 mL, respectively. For clinically relevant fluid accumulations (≥300 mL), the predicted impedance change exceeded 2 Ω, indicating practical detectability. Frequency-domain analysis (5–1000 kHz) further demonstrated consistent impedance contrast across the investigated range. These findings suggest that tetrapolar electrical impedance measurements have the potential for continuous monitoring of pulmonary fluid changes and provide a foundation for future experimental validation in human subjects.

Schlagwörter

Stichwörter der Autor:innen

BioimpedanceFEM modelinglung fluidpulmonary edemasegmentation

Autor:innen und Institutionen

  • Department of Biomedical Physics and Technology, University of Dhaka, Dhaka, 1000, Bangladesh.
  • Department of Sciences, BGMEA University of Fashion and Technology, Dhaka, 1230, Bangladesh.
  • Department of Electrical and Electronic Engineering, Bangladesh Army University of Science and Technology, Saidpur, Bangladesh.
  • Division of Physics, Department of Arts and Sciences, Ahsanullah University of Science and Technology, Dhaka, 1208, Bangladesh.

Zitieren

APA

Mortuza, F., Kabir, M. S., Molla, M. Z., Al Imran, M. I., & Abdul Kadir, M. (2026). Finite element modeling of human thorax for electrical bioimpedance based monitoring of pulmonary fluid accumulation. Journal of Electrical Bioimpedance, 17(1), 4-13. https://doi.org/10.2478/joeb-2026-0002

Vancouver

Mortuza F, Kabir MS, Molla MZ, Al Imran MI, Abdul Kadir M. Finite element modeling of human thorax for electrical bioimpedance based monitoring of pulmonary fluid accumulation. Journal of Electrical Bioimpedance. 2026;17(1):4-13. doi:10.2478/joeb-2026-0002

BibTeX
@article{Mortuza2026,
  author = {Mortuza, Frijia and Kabir, Md Shahriar and Molla, Md Zaman and Al Imran, Md Ibrahim and Abdul Kadir, Muhammad},
  title = {Finite element modeling of human thorax for electrical bioimpedance based monitoring of pulmonary fluid accumulation},
  journal = {Journal of Electrical Bioimpedance},
  year = {2026},
  volume = {17},
  number = {1},
  pages = {4--13},
  doi = {10.2478/joeb-2026-0002}
}