EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Validation of non-empirical fat-free mass estimation model for a wrist-worn device

Aleksandr Polokhin, Anna Pronina, Andrey Boev, Stas Gorbunov

Journal of Electrical Bioimpedance · 25.06.2022 · 13 (1) · 31-38

DOI: 10.2478/joeb-2022-0006 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrical Bioimpedance, online erschienen am 25.06.2022. Verfasst von Aleksandr Polokhin und 3 weiteren Autor:innen. Beteiligte Einrichtung: AURA Devices, Inc., Wilmington, DE, USA. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Fat-free mass (FFM) estimation has dramatic importance for body composition evaluation, often providing a basis for treatment of obesity and muscular dystrophy. However, current methods of FFM estimation have several drawbacks, usually related to either cost-effectiveness and equipment size (dual-energy X-ray absorptiometry (DEXA) scan) or model limitations. In this study, we present and validate a new FFM estimation model based on hand-to-hand bioimpedance analysis (BIA) and arm volume. Forty-two participants underwent a full-body DEXA scan, a series of anthropometric measurements, and upper-body BIA measurements with the custom-designed wearable wrist-worn impedance meter. A new two truncated cones (TTC) model was trained on DEXA data and achieved the best performance metrics of 0.886 ± 0.051 r 2 , 0.052 ± 0.009 % mean average error, and 6.884 ± 1.283 kg maximal residual error in FFM estimation. The model further demonstrated its effectiveness in Bland-Altman comparisons with the skinfold thickness-based FFM estimation method, achieving the least mean bias (0.007 kg). The novel TTC model can provide an alternative to full-body BIA measurements, demonstrating an accurate FFM estimation independently of population variables.

Schlagwörter

Stichwörter der Autor:innen

Bioelectrical impedance analysisfat free massmultiple linear regressionpredictive modelingupper-body measurement

Autor:innen und Institutionen

  • AURA Devices, Inc., Wilmington, DE, USA.

Zitieren

APA

Polokhin, A., Pronina, A., Boev, A., & Gorbunov, S. (2022). Validation of non-empirical fat-free mass estimation model for a wrist-worn device. Journal of Electrical Bioimpedance, 13(1), 31-38. https://doi.org/10.2478/joeb-2022-0006

Vancouver

Polokhin A, Pronina A, Boev A, Gorbunov S. Validation of non-empirical fat-free mass estimation model for a wrist-worn device. Journal of Electrical Bioimpedance. 2022;13(1):31-38. doi:10.2478/joeb-2022-0006

BibTeX
@article{Polokhin2022,
  author = {Polokhin, Aleksandr and Pronina, Anna and Boev, Andrey and Gorbunov, Stas},
  title = {Validation of non-empirical fat-free mass estimation model for a wrist-worn device},
  journal = {Journal of Electrical Bioimpedance},
  year = {2022},
  volume = {13},
  number = {1},
  pages = {31--38},
  doi = {10.2478/joeb-2022-0006}
}
Kostenlos starten →