EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Tracking fault of distribution single core underground power cable by FBG wavelength

M. Hazwan Wahab, Mohammad Syuhaimi Ab-Rahman, Ahmad Asrul Ibrahim, A. H. Ahmad Abas, Norhidayah Ahmad

Journal of Electrical Engineering · 01.06.2026 · 77 (3) · 339-345

DOI: 10.2478/jee-2026-0032 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Electrical Engineering, online erschienen am 17.06.2026. Verfasst von M. Hazwan Wahab und 4 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents on FBG Code Supervision into Single Core Underground Cable Power Line for Health Condition. Fiber Bragg Grating (FBG) is a novel technique for network health monitoring, offering numerous advantages such as high precision, multiplexing capabilities, resistance to electromagnetic interference, and excellent repeatability. The FBG sensor integrated into the network has been employed in numerous applications to monitor system and environmental conditions. Any interruption on the system or environment can be sensed and monitored through the status of network health. A consistent Fiber Bragg Grating (FBG) array situated before and after the splitter will be utilized to reflect the optical signal that has been transferred along the fiber. As the network’s FBGs use different wavelengths to represent each line connection, FBG codes will serve as an indicator between one connection to another. In this paper, a new technique is shown to monitor network health for single core underground cable by developing fault branch identification FBG configuration designs (FBG codes) up to 36 branches while maintaining quality of power transmission. Its capabilities are confirmed by simulations using real model data and it shows the potential to solve the various problems presently we have.

Zitieren

APA

Wahab, M. H., Ab-Rahman, M. S., Ibrahim, A. A., Abas, A. H. A., & Ahmad, N. (2026). Tracking fault of distribution single core underground power cable by FBG wavelength. Journal of Electrical Engineering, 77(3), 339-345. https://doi.org/10.2478/jee-2026-0032

Vancouver

Wahab MH, Ab-Rahman MS, Ibrahim AA, Abas AHA, Ahmad N. Tracking fault of distribution single core underground power cable by FBG wavelength. Journal of Electrical Engineering. 2026;77(3):339-345. doi:10.2478/jee-2026-0032

BibTeX
@article{Wahab2026,
  author = {Wahab, M. Hazwan and Ab-Rahman, Mohammad Syuhaimi and Ibrahim, Ahmad Asrul and Abas, A. H. Ahmad and Ahmad, Norhidayah},
  title = {Tracking fault of distribution single core underground power cable by FBG wavelength},
  journal = {Journal of Electrical Engineering},
  year = {2026},
  volume = {77},
  number = {3},
  pages = {339--345},
  doi = {10.2478/jee-2026-0032}
}
Kostenlos starten →