Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic Load

Romaih O. Mostafa, Sofyan Y. Ahmed, Jasim A. Abdullah

Civil and Environmental Engineering · 20.11.2026

DOI: 10.2478/cee-2027-0038 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Civil and Environmental Engineering, online erschienen am 20.11.2026. Verfasst von Romaih O. Mostafa und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The cyclic performance and post-damage rehabilitation of non-prismatic reinforced concrete columns, remain insufficiently characterized. This study investigates the axial, pushover, and cyclic behaviour of non-prismatic RC columns and evaluates two rehabilitation techniques-ferrocement jacketing and steel-plate jacketing-applied after yield-level damage. Eight non-prismatic columns were fabricated and tested. Two control specimens were loaded axially to failure to establish load-carrying capacity; two underwent pushover testing at 20% and 40% axial load ratios to determine yield displacement; and four were subjected to yield-level reversed cyclic loading to induce controlled permanent deformation, then repaired with a 25 mm ferrocement jacket or a 2.71 mm steel-plate jacket and retested under quasistatic cyclic protocol. The columns achieved an average axial capacity of 905 kN and failed in shear at the necking region. Increasing the axial loading ratio from 20% to 40% reduced the yield displacement from 7.35 mm to 5.7 mm (22.5%) and lowered dissipated hysteretic energy by approximately 21%, while increasing lateral strength by 86%. Both rehabilitation techniques effectively restored strength and stiffness: steel jacketing delivered partial stiffness recovery and higher performance levels, whereas ferrocement delivered full stiffness recovery and dissipated marginally more energy (9% higher at 20% axial load). Increasing the sustained load from 20% to 40% narrows the difference of the total energy dissipated in both types of rehabilitation. Steel jacketing is the preferable choice where residual-drift control is the governing design criterion, while ferrocement remains a viable, more economical alternative where moderate ductility demand and lower axial load ratios are expected.

Zitieren

APA

Mostafa, R. O., Ahmed, S. Y., & Abdullah, J. A. (2026). Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic Load. Civil and Environmental Engineering. https://doi.org/10.2478/cee-2027-0038

Vancouver

Mostafa RO, Ahmed SY, Abdullah JA. Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic Load. Civil and Environmental Engineering. 2026. doi:10.2478/cee-2027-0038

BibTeX
@article{Mostafa2026,
  author = {Mostafa, Romaih O. and Ahmed, Sofyan Y. and Abdullah, Jasim A.},
  title = {Investigating the Performance of Rehabilitated Non-Prismatic Reinforced Concrete Columns Subjected to Cyclic Load},
  journal = {Civil and Environmental Engineering},
  year = {2026},
  doi = {10.2478/cee-2027-0038}
}
Kostenlos starten →