EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Flexural Repair of Pre-Loaded and Pre-Damaged RC Beams Using Anchored Hybrid FRP Composites

Yaman Sami Shareef Al-Kamaki

Civil and Environmental Engineering · 01.12.2025 · 21 (2) · 1113-1126

DOI: 10.2478/cee-2025-0083 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Civil and Environmental Engineering, online erschienen am 02.07.2025. Verfasst von Yaman Sami Shareef Al-Kamaki. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

External fiber-reinforced polymer (FRP) composites are the supreme recent approach for rehabilitating, repairing, and strengthening reinforced concrete (RC) members. FRP can substantially enhance deteriorated members’ shear and flexural capacity and extend their useful life. This experimental work addresses the flexural behavior of RC beams strengthened with hybrid carbon fiber reinforced polymer (CFRP) plates and fabrics (sheets) made of carbon, basalt, or glass fiber reinforced polymers (CFRP/BFRP/GFRP). The anticipated hybrid approach aims to enhance the characteristics of the strengthening beams by combining high-strength CFRP laminates with FRP sheets using epoxy adhesive. Five 230 mm × 260 mm × 1600 mm RC beams were pre-loaded up to 75% of the ultimate load of the reference beam (control beam), pre-damaged, strengthened, and tested under a 3-point bending scheme. One beam served as an un-strengthened control, while one was strengthened with a single CFRP laminate (plate) along the beam’s centreline. The rest three beams were strengthened with a CFRP plate, with additional anchorage at the ends using CFRP, BFRP, or GFRP sheets. The beams that were strengthened beams exhibited a remarkable improvement in load-bearing capacity associated with the unstrengthened control beam. CFRP strengthening with U-wrap anchorage increased the ultimate load of RC beams by up to 45% compared to the unstrengthened beam, while deflection was reduced by approximately 64%, indicating improved strength and stiffness.

Zitieren

APA

Al-Kamaki, Y. S. S. (2025). Flexural Repair of Pre-Loaded and Pre-Damaged RC Beams Using Anchored Hybrid FRP Composites. Civil and Environmental Engineering, 21(2), 1113-1126. https://doi.org/10.2478/cee-2025-0083

Vancouver

Al-Kamaki YSS. Flexural Repair of Pre-Loaded and Pre-Damaged RC Beams Using Anchored Hybrid FRP Composites. Civil and Environmental Engineering. 2025;21(2):1113-1126. doi:10.2478/cee-2025-0083

BibTeX
@article{AlKamaki2025,
  author = {Al-Kamaki, Yaman Sami Shareef},
  title = {Flexural Repair of Pre-Loaded and Pre-Damaged RC Beams Using Anchored Hybrid FRP Composites},
  journal = {Civil and Environmental Engineering},
  year = {2025},
  volume = {21},
  number = {2},
  pages = {1113--1126},
  doi = {10.2478/cee-2025-0083}
}
Kostenlos starten →