EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis

Dragana Mutavdžić Pavlović iD, Sandra Babić iD, Mirta Čizmić, Miranda Sertić iD, Tea Pinušić

Acta Pharmaceutica · 2023

DOI: 10.2478/acph-2023-0041 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Pharmaceutica, 2023. Verfasst von Dragana Mutavdžić Pavlović und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1University of Zagreb Faculty of Chemical Engineering and Technology, Department of Analytical Chemistry, 10000 Zagreb, Croatia. Hauptthemen laut MEDLINE: Macrolides, Roxithromycin. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Solid-phase extraction (SPE) coupled with capillary electrophoresis (CE) for the determination of macrolide antibiotics (azithromycin, clarithromycin, roxithromycin, tylosin) and tiamulin in water samples was described in this article. These compounds were extracted with different types of sorbents ( Oasis HLB, C18, C8, SDB, and Strata-X) and different masses of sorbents (60 mg, 200 mg, and 500 mg) using different organic solvents (methanol, ethanol, and acetonitrile) and different pH values of water samples (pH 7.00, 8.00, and 9.00). It was found that the highest extraction efficiency of the studied compounds was obtained with 200 mg/3 mL C18 cartridges with methanol as eluent at pH 9.00 of the water sample. The developed SPE-CE method for macrolide antibiotics and tiamulin was validated for linearity, precision, repeatability, the limit of detection ( LOD ), the limit of quantification ( LOQ ), and recovery. Good linearity was obtained in the range of 0.3–30 mg L −1 depending on the drug, with correlation coefficients higher than 0.9958 in all cases except clarithromycin (0.9873). Expanded measurement uncertainties were calculated for each pharmaceutical, accounting for 20.31 % (azithromycin), 38.33 % (tiamulin), 28.95 % (clarithromycin), 26.99 % (roxithromycin), and 21.09 % (tiamulin). Uncertainties associated with precision and calibration curves contributed the most to the combined measurement uncertainty. The method was successfully applied to the analysis of production waste-water from the pharmaceutical industry.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

MacrolidesRoxithromycinClarithromycinMethanolAzithromycinAnti-Bacterial AgentsWaterElectrophoresis, CapillarySolid Phase ExtractionChromatography, High Pressure LiquidDiterpenes

Stichwörter der Autor:innen

capillary electrophoresismacrolidesmeasurement uncertaintysolid-phase extractiontiamulinwastewater

Substanzen

MacrolidesClarithromycinRoxithromycinMethanolAzithromycinAnti-Bacterial AgentsWatertiamulinDiterpenes

Autor:innen und Institutionen

  • 1University of Zagreb Faculty of Chemical Engineering and Technology, Department of Analytical Chemistry, 10000 Zagreb, Croatia.
  • 2University of Zagreb Faculty of Pharmacy and Biochemistry, Department of Pharmaceutical Analysis, 10000 Zagreb, Croatia.

ORCID-Profile: Dragana Mutavdžić Pavlović, Sandra Babić, Miranda Sertić

Zitieren

APA

Pavlović, D. M., Babić, S., Čizmić, M., Sertić, M., & Pinušić, T. (2023). Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis. Acta Pharmaceutica. https://doi.org/10.2478/acph-2023-0041

Vancouver

Pavlović DM, Babić S, Čizmić M, Sertić M, Pinušić T. Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis. Acta Pharmaceutica. 2023. doi:10.2478/acph-2023-0041

BibTeX
@article{Pavlovi2023,
  author = {Pavlović, Dragana Mutavdžić and Babić, Sandra and Čizmić, Mirta and Sertić, Miranda and Pinušić, Tea},
  title = {Simultaneous determination of macrolides in water samples by solid-phase extraction and capillary electrophoresis},
  journal = {Acta Pharmaceutica},
  year = {2023},
  doi = {10.2478/acph-2023-0041}
}
Kostenlos starten →