Fachartikel in der Zeitschrift Magnetic Resonance in Medical Sciences, 2026. Verfasst von Tatsuya Koizumi und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Juntendo University Hospital, Tokyo, Japan. Hauptthemen laut MEDLINE: Saliva, Sialography, Magnetic Resonance Imaging, Cine, Salivary Glands. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Purpose
This study evaluated salivary gland function using MR cine sialography (MRCS) based on the time-spatial labeling inversion pulse (Time-SLIP) technique combined with a deep learning reconstruction–based denoising method (dDLR). Bilateral salivary flow from the submandibular glands (SMGs) and parotid glands (PGs) was visualized, and its correlation with whole-saliva volume was examined.
Methods
Optimal MRCS parameters were identified, and imaging was performed in 11 healthy volunteers. Correlations between salivary flow on MRCS and unstimulated whole-saliva volume (UWS) and stimulated whole-saliva volume (SWS), as well as side-to-side differences, were analyzed. UWS was obtained using the spitting method, and SWS was obtained using the gum-chewing test. Salivary-flow distance was defined as the length from the labeling position to the point where the labeled saliva signal became indistinguishable from background signal. Spearman’s rank correlation coefficients (ρ) were calculated to evaluate the association between whole-saliva volume and MRCS, and Wilcoxon’s signed-rank test was used to assess side-to-side differences.
Results
Correlation coefficients between MRCS and whole-saliva volume were as follows: under unstimulated conditions, SMG ρ = 0.825, PG ρ = −0.05, SMG + PG ρ = 0.802; under stimulated conditions, SMG ρ = 0.606, PG ρ = 0.72, and SMG + PG ρ = 0.820. Strong correlations (ρ > 0.8) were observed for SMG and SMG + PG under unstimulated conditions and for SMG + PG under stimulation. No significant overall side-to-side differences were found except for PG under stimulation (P = 0.016). However, several individuals showed notable side-to-side differences, underscoring the value of bilateral imaging.
Conclusion
Bilateral SMG and PG salivary flows obtained using MRCS with dDLR showed strong correlations with UWS and SWS. These findings suggest that MRCS is a promising noninvasive method for assessing salivary volume and supports both separate and combined evaluation of SMG and PG function.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Juntendo University Hospital, Tokyo, Japan.
- Department of Medical Radiological Technology, Graduate School of Health Sciences, Juntendo University, Tokyo, Japan.
- Department of Radiology, Juntendo University Urayasu Hospital, Urayasu Chiba, Japan.
- Department of Radiology, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
- Center for Promotion of Data Science, Graduate School of Medicine, Juntendo University, Tokyo, Japan.
Zitieren
APA
Koizumi, T., Goto, M., Kogure, Y., Kawasaki, H., Nagasawa, T., Hojo, N., Saito, N., Kyogoku, S., & Kuwatsuru, R. (2026). A Novel MR Cine Sialography Technique for Evaluating Salivary Gland Function: Correlation with Unstimulated and Stimulated Saliva Volumes. Magnetic Resonance in Medical Sciences, 25(2), n/a. https://doi.org/10.2463/mrms.mp.2026-0004
Vancouver
Koizumi T, Goto M, Kogure Y, Kawasaki H, Nagasawa T, Hojo N, et al. A Novel MR Cine Sialography Technique for Evaluating Salivary Gland Function: Correlation with Unstimulated and Stimulated Saliva Volumes. Magnetic Resonance in Medical Sciences. 2026;25(2):n/a. doi:10.2463/mrms.mp.2026-0004
BibTeX
@article{Koizumi2026,
author = {Koizumi, Tatsuya and Goto, Masami and Kogure, Yosuke and Kawasaki, Hideo and Nagasawa, Toru and Hojo, Noboru and Saito, Naoko and Kyogoku, Shinsuke and Kuwatsuru, Ryohei},
title = {A Novel MR Cine Sialography Technique for Evaluating Salivary Gland Function: Correlation with Unstimulated and Stimulated Saliva Volumes},
journal = {Magnetic Resonance in Medical Sciences},
year = {2026},
volume = {25},
number = {2},
pages = {n/a},
doi = {10.2463/mrms.mp.2026-0004}
}
EUVIMED