EUVIMEDEUVIMED entdecken
Open Access

Identification of the Distal Dural Ring Using Three-dimensional Motion-sensitized Driven-equilibrium Prepared T1-weighted Fast Spin Echo Imaging: Application to Paraclinoid Aneurysms

Maya Oki, Tatsuya Oki, Ryuta Ito, Neil Roberts, Yoshiyuki Watanabe

Magnetic Resonance in Medical Sciences · 2025

DOI: 10.2463/mrms.mp.2024-0084 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medical Sciences, 2025. Verfasst von Maya Oki und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Magnetic Resonance Angiography, Intracranial Aneurysm, Dura Mater. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: This study investigated the ability of three-dimentional motion-sensitized driven-equilibrium prepared T1-weighted fast spin echo (3D MSDE-FSE) imaging to identify distal dural rings (DDRs) and paraclinoid aneurysms (ParaC-ANs) and differentiate between intradural and extradural ParaC-ANs and compared it with that of established MR cisternography-based techniques. METHODS: 3D MSDE-FSE images were acquired along with fast imaging employing steady state acquisition (FIESTA), and time-of-flight magnetic resonance angiography (TOF-MRA) on a 3T MRI system in 53 patients with unruptured and untreated ParaC-ANs. Two radiologists applied a 3-point scale to rate the clarity with which the DDR (53 left and 53 right) and ParaC-ANs (total of 55) were depicted in the 3D MSDE-FSE and FIESTA images. The clarity scores, which were determined by averaging the scores of the 2 assessors, on the 3D MSDE-FSE and FIESTA images were compared using the Wilcoxon signed-rank test. Furthermore, the same radiologists classified the ParaC-ANs as intradural, extradural, or transitional on 3D MSDE-FSE images. A third radiologist independently classified the ParaC-ANs as intradural, extradural, or transitional based on the FIESTA and MRA fusion images. The kappa coefficient was used to compare this classification with that based on 3D MSDE-FSE images. RESULTS: The Wilcoxon signed-rank test revealed no significant difference between 3D MSDE-FSE images and FIESTA images in the scores for the clarity of depiction of the DDRs (P = 0.119). However, the scores for the clarity of the depiction of the ParaC-ANs were significantly greater for the 3D MSDE-FSE images than for the FIESTA images (P < 0.001). The kappa coefficient for comparison of classification based on 3D MSDE-FSE images and FIESTA and MRA fusion images was 0.82. CONCLUSION: 3D MSDE-FSE imaging has the potential to differentiate between intradural and extradural ParaC-ANs by directly recognizing the DDR.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMagnetic Resonance AngiographyIntracranial AneurysmDura MaterMagnetic Resonance ImagingHumansFemaleMiddle AgedMaleAgedAdultAged, 80 and overReproducibility of ResultsMotion

Stichwörter der Autor:innen

distal dural ringfast imaging employing steady state acquisitionmotion-sensitized driven-equilibrium preparationparaclinoid aneurysm

Autor:innen und Institutionen

  • Department of Radiology, Shiga University of Medical Science, Otsu, Shiga, Japan.

Zitieren

APA

Oki, M., Oki, T., Ito, R., Roberts, N., & Watanabe, Y. (2025). Identification of the Distal Dural Ring Using Three-dimensional Motion-sensitized Driven-equilibrium Prepared T1-weighted Fast Spin Echo Imaging: Application to Paraclinoid Aneurysms. Magnetic Resonance in Medical Sciences. https://doi.org/10.2463/mrms.mp.2024-0084

Vancouver

Oki M, Oki T, Ito R, Roberts N, Watanabe Y. Identification of the Distal Dural Ring Using Three-dimensional Motion-sensitized Driven-equilibrium Prepared T1-weighted Fast Spin Echo Imaging: Application to Paraclinoid Aneurysms. Magnetic Resonance in Medical Sciences. 2025. doi:10.2463/mrms.mp.2024-0084

BibTeX
@article{Oki2025,
  author = {Oki, Maya and Oki, Tatsuya and Ito, Ryuta and Roberts, Neil and Watanabe, Yoshiyuki},
  title = {Identification of the Distal Dural Ring Using Three-dimensional Motion-sensitized Driven-equilibrium Prepared T1-weighted Fast Spin Echo Imaging: Application to Paraclinoid Aneurysms},
  journal = {Magnetic Resonance in Medical Sciences},
  year = {2025},
  doi = {10.2463/mrms.mp.2024-0084}
}
Kostenlos starten →