EUVIMEDEUVIMED entdecken
Open Access

Evaluating Biliary Malignancy with Measured and Calculated Ultra-high b-value Diffusion-weighted MR Imaging at 3T

Minkyeong Kim, Tae Young Lee, Byeong Seong Kang, Woon Jung Kwon, Soyeoun Lim, Gyeong Min Park, Minseo Bang

Magnetic Resonance in Medical Sciences · 2024

DOI: 10.2463/mrms.mp.2022-0144 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Magnetic Resonance in Medical Sciences, 2024. Verfasst von Minkyeong Kim und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine. Hauptthemen laut MEDLINE: Diffusion Magnetic Resonance Imaging, Biliary Tract Neoplasms. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

PURPOSE: Although diffusion-weighted imaging (DWI) with ultra-high b-values is reported to be advantageous in the detection of some tumors, its applicability is not yet known in biliary malignancy. Therefore, this study aimed to evaluate the impact of measured b = 1400 s/mm2 (M1400) and calculated b = 1400 s/mm2 (C1400) DWI on image quality and quality of lesion discernibility using a modern 3T MR system compared to conventional b = 800 s/mm2 DWI (M800). METHODS: We evaluated 56 patients who had pathologically proven biliary malignancy. All the patients underwent preoperative or baseline 3T MRI using DWI (b = 50, 400, 800, and 1400 s/mm2). The calculated DWI was obtained using a conventional DWI set (b = 50, 400, and 800). The tumor-to-bile contrast ratio (CR) and tumor SNR were compared between the different DWI images. Likert scores were given on a 5-point scale to assess the overall image quality, overall artifacts, ghost artifacts, misregistration artifacts, margin sharpness, and lesion discernibility. Repeated-measures analysis of variance with post hoc analyses was used for statistical evaluations. RESULTS: The CR of the tumor-to-bile was significantly higher in both M1400 and C1400 than in M800 (Pa < 0.01). SNRs were significantly higher in M800, followed by C1400 and M1400 (Pa < 0.01). Lesion discernibility was significantly improved for M1400, followed by C1400 and M800 for both readers (Pa < 0.01). CONCLUSION: Using a 3T MRI, both measured and calculated DWI with an ultra-high b-value offer superior lesion discernibility for biliary malignancy compared to the conventional DWI.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Diffusion Magnetic Resonance ImagingBiliary Tract NeoplasmsHumansFemaleMaleMiddle AgedAgedAdultAged, 80 and overArtifactsImage Interpretation, Computer-AssistedReproducibility of ResultsRetrospective StudiesSignal-To-Noise RatioImage Enhancement

Stichwörter der Autor:innen

biliary malignancydiffusion-weighted imageultra-high b-value

Autor:innen und Institutionen

  • Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine.

Zitieren

APA

Kim, M., Lee, T. Y., Kang, B. S., Kwon, W. J., Lim, S., Park, G. M., & Bang, M. (2024). Evaluating Biliary Malignancy with Measured and Calculated Ultra-high b-value Diffusion-weighted MR Imaging at 3T. Magnetic Resonance in Medical Sciences. https://doi.org/10.2463/mrms.mp.2022-0144

Vancouver

Kim M, Lee TY, Kang BS, Kwon WJ, Lim S, Park GM, et al. Evaluating Biliary Malignancy with Measured and Calculated Ultra-high b-value Diffusion-weighted MR Imaging at 3T. Magnetic Resonance in Medical Sciences. 2024. doi:10.2463/mrms.mp.2022-0144

BibTeX
@article{Kim2024,
  author = {Kim, Minkyeong and Lee, Tae Young and Kang, Byeong Seong and Kwon, Woon Jung and Lim, Soyeoun and Park, Gyeong Min and Bang, Minseo},
  title = {Evaluating Biliary Malignancy with Measured and Calculated Ultra-high b-value Diffusion-weighted MR Imaging at 3T},
  journal = {Magnetic Resonance in Medical Sciences},
  year = {2024},
  doi = {10.2463/mrms.mp.2022-0144}
}
Kostenlos starten →