Influence of Diffusion Time and Temperature on Restricted Diffusion Signal: A Phantom Study
Magnetic Resonance in Medical Sciences · 2024
DOI: 10.2463/mrms.mp.2022-0103 ↗Kurz gefasst
Fachartikel in der Zeitschrift Magnetic Resonance in Medical Sciences, 2024. Verfasst von Hinako Oshiro und 7 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of Human Health Sciences, Tokyo Metropolitan University. Hauptthemen laut MEDLINE: Magnetic Resonance Imaging, Diffusion Magnetic Resonance Imaging. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 37 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Japan Agency for Medical Research and Development, Japan Society for the Promotion of Science, Ministry of Education, Culture, Sports, Science and Technology.
Abstract (Originalsprache)
PURPOSE: Diffusion MRI is a physical measurement method that quantitatively indicates the displacement of water molecules diffusing in voxels. However, there are insufficient data to characterize the diffusion process physically in a uniform structure such as a phantom. This study investigated the transitional relationship between structure scale, temperature, and diffusion time for simple restricted diffusion using a capillary phantom. METHODS: We performed diffusion-weighted pulsed-gradient stimulated-echo acquisition mode (STEAM) MRI with a 9.4 Tesla MRI system (Bruker BioSpin, Ettlingen, Germany) and a quadrature coil with an inner diameter of 86 mm (Bruker BioSpin). We measured the diffusion coefficients (radial diffusivity [RD]) of capillary plates (pore sizes 6, 12, 25, 50, and 100 μm) with uniformly restricted structures at various temperatures (10ºC, 20ºC, 30ºC, and 40ºC) and multiple diffusion times (12-800 ms). We evaluated the characteristics of scale, temperature, and diffusion time for restricted diffusion. RESULTS: The RD decayed and became constant depending on the structural scale. Diffusion coefficient fluctuations with temperature occurred mostly under conditions of a large structural scale and short diffusion time. We obtained data suggesting that temperature-dependent changes in the diffusion coefficients follow physical laws. CONCLUSION: No water molecules were observed outside the glass tubes in the capillary plates, and the capillary plates only reflected a restricted diffusion process within the structure.We experimentally evaluated the characteristics of simple restricted diffusion to reveal the transitional relationship of the diffusion coefficient with diffusion time, structure scale, and temperature through composite measurement.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Graduate School of Human Health Sciences, Tokyo Metropolitan University.
- Center for Brain Science, RIKEN.
- School of Medicine, Keio University.
- Division of Regenerative Medicine, The Jikei University School of Medicine.
Förderung
- Japan Agency for Medical Research and Development
- Japan Society for the Promotion of Science
- Ministry of Education, Culture, Sports, Science and Technology
Zitieren
APA
Oshiro, H., Hata, J., Nakashima, D., Hayashi, N., Haga, Y., Hagiya, K., Yoshimaru, D., & Okano, H. (2024). Influence of Diffusion Time and Temperature on Restricted Diffusion Signal: A Phantom Study. Magnetic Resonance in Medical Sciences. https://doi.org/10.2463/mrms.mp.2022-0103
Vancouver
Oshiro H, Hata J, Nakashima D, Hayashi N, Haga Y, Hagiya K, et al. Influence of Diffusion Time and Temperature on Restricted Diffusion Signal: A Phantom Study. Magnetic Resonance in Medical Sciences. 2024. doi:10.2463/mrms.mp.2022-0103
BibTeX
@article{Oshiro2024,
author = {Oshiro, Hinako and Hata, Junichi and Nakashima, Daisuke and Hayashi, Naoya and Haga, Yawara and Hagiya, Kei and Yoshimaru, Daisuke and Okano, Hideyuki},
title = {Influence of Diffusion Time and Temperature on Restricted Diffusion Signal: A Phantom Study},
journal = {Magnetic Resonance in Medical Sciences},
year = {2024},
doi = {10.2463/mrms.mp.2022-0103}
}
EUVIMED