Weekly terminal cleaning is recommended to maintain low airborne bacterial counts in operating rooms
Journal of the American Veterinary Medical Association · 01.12.2026 · 264 (12) · 1-9
DOI: 10.2460/javma.26.05.0397 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Veterinary Medical Association, erschienen am 01.12.2026. Verfasst von Alison Pankowski und 6 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX. Hauptthemen laut MEDLINE: Air Microbiology, Operating Rooms, Hospitals, Animal. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To identify the maximum recommended duration between terminal cleaning events in small animal veterinary operating rooms (ORs) and explore factors contributing to increased airborne microbial load.
Methods
An observational study using agar settle plates was completed to measure the Index of Microbial Air contamination (IMA) across ORs in a veterinary teaching hospital over a 2-year period. Plates were exposed for 60 minutes during surgeries and incubated for 48 hours to measure IMA.
Results
The median IMA for 192 collected cases was 4.3, below the published OR benchmark of 25 IMA, with a median terminal cleaning interval of 48 hours. Univariable linear regression implied that increasing time after terminal cleaning was associated (β = 0.002; 95% CI, 0.0002 to 0.003) with an increase in air contamination. For each 10-hour delay in cleaning, bacteria count increased by 1.04 IMA. Significant associations were also found between IMA and total number of personnel in the OR. In exploratory univariable analyses, significant relationships were not identified between IMA and procedure classification, number of scrubbed personnel, or postoperative surgical site infection.
Conclusions
Settle plates offer a practical, cost-effective method for monitoring air hygiene and evaluating cleaning protocols. Our methodology confirms that terminal cleaning has a measurable effect in reducing OR air contamination and indicates weekly terminal cleaning events to maintain appropriate OR airborne microbial counts would be beneficial. Clinical Relevance Terminal cleaning should be completed at least every 10 days in veterinary ORs to keep microbial air contamination at levels below the working OR threshold of 25 IMA.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 1Department of Small Animal Clinical Sciences, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX.
- 2Small Animal Teaching Hospital, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX.
- 3Department of Veterinary Pathobiology, College of Veterinary Medicine and Biomedical Sciences, Texas A&M University, College Station, TX.
ORCID-Profile: Nicholas Jeffery, Artem S Rogovskyy, Kelley M Thieman
Zitieren
APA
Pankowski, A., Jeffery, N., Wendler, K., Douglas, P., Rogovskyy, A. S., Sanders, D., & Thieman, K. M. (2026). Weekly terminal cleaning is recommended to maintain low airborne bacterial counts in operating rooms. Journal of the American Veterinary Medical Association, 264(12), 1-9. https://doi.org/10.2460/javma.26.05.0397
Vancouver
Pankowski A, Jeffery N, Wendler K, Douglas P, Rogovskyy AS, Sanders D, et al. Weekly terminal cleaning is recommended to maintain low airborne bacterial counts in operating rooms. Journal of the American Veterinary Medical Association. 2026;264(12):1-9. doi:10.2460/javma.26.05.0397
BibTeX
@article{Pankowski2026,
author = {Pankowski, Alison and Jeffery, Nicholas and Wendler, Katy and Douglas, Pamela and Rogovskyy, Artem S and Sanders, David and Thieman, Kelley M},
title = {Weekly terminal cleaning is recommended to maintain low airborne bacterial counts in operating rooms},
journal = {Journal of the American Veterinary Medical Association},
year = {2026},
volume = {264},
number = {12},
pages = {1--9},
doi = {10.2460/javma.26.05.0397}
}