Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life
Journal of the American Veterinary Medical Association · 2025
DOI: 10.2460/javma.24.09.0586 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Veterinary Medical Association, 2025. Verfasst von Matteo Rossanese und 7 weiteren Autor:innen. Beteiligte Einrichtung: 1Department of Clinical Science and Services, Royal Veterinary College, University of London, Hatfield, UK. Hauptthemen laut MEDLINE: Pacemaker, Artificial, Cat Diseases, Quality of Life, Bradycardia. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE To describe complications and outcomes in cats undergoing epicardial pacemaker (EP) implantation for artificial cardiac pacing and to investigate improvement in clinical signs and health-related quality of life (HRQoL) following surgery. METHODS 39 client-owned cats that underwent EP placement. Medical records of 4 UK-based referral hospitals were searched and data reviewed retrospectively between July 2010 and December 2022. An HRQoL questionnaire was used to assess outcomes and HRQoL. RESULTS The primary reasons for referral included collapsing episodes (n = 27) and bradycardia (31). Third-degree atrioventricular block (29 of 39) was the predominant indication for pacemaker placement. Intra- and postoperative complications were documented in 3 of 39 and 14 of 39 cats, respectively. All cats survived to discharge, and median follow-up time was 719 days (range, 9 to 2,285 days). Owners reported improvement in clinical signs, high level of satisfaction, and improved HRQoL. CONCLUSIONS Epicardial pacemaker placement effectively resolves clinical signs of bradyarrhythmias in cats, leading to significant improvements in HRQoL. Postoperative complications are common but do not impact the overall outcome. Cats undergoing EP placement have an excellent HRQoL with an improvement in clinical signs and a high level of owner satisfaction. CLINICAL RELEVANCE Epicardial pacemaker placement is the current method of choice for cats showing clinical signs and requiring artificial cardiac pacing. Despite the occurrence of postoperative complications, these did not adversely impact overall outcomes, with high owner satisfaction reported.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 1Department of Clinical Science and Services, Royal Veterinary College, University of London, Hatfield, UK.
- 2Langford Vets Small Animal Referral Hospital, University of Bristol, Bristol, UK.
- 3North Down Specialist Referrals, Bletchingley, UK.
- 4Small Animal Teaching Hospital, University of Liverpool, Neston, UK.
Zitieren
APA
Rossanese, M., Brockman, D., Chanoit, G., Scott, P., de la Puerta, B., Crosland, A., Dukes-McEwan, J., & Basili, M. (2025). Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life. Journal of the American Veterinary Medical Association. https://doi.org/10.2460/javma.24.09.0586
Vancouver
Rossanese M, Brockman D, Chanoit G, Scott P, de la Puerta B, Crosland A, et al. Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life. Journal of the American Veterinary Medical Association. 2025. doi:10.2460/javma.24.09.0586
BibTeX
@article{Rossanese2025,
author = {Rossanese, Matteo and Brockman, Dan and Chanoit, Guillaume and Scott, Peter and de la Puerta, Benito and Crosland, Andrew and Dukes-McEwan, Joanna and Basili, Mattia},
title = {Epicardial pacemaker placement in cats is associated with resolution of clinical signs and excellent quality of life},
journal = {Journal of the American Veterinary Medical Association},
year = {2025},
doi = {10.2460/javma.24.09.0586}
}
EUVIMED