EUVIMEDEUVIMED entdecken
Crossref

Abdominal ultrasound has inconsistent agreement with subsequent surgery or necropsy findings in dogs and cats with septic peritonitis

Curtis G Rheingold, Cody Dickens, Anna Tran iD, Rebecka S Hess, Yekaterina Buriko

Journal of the American Veterinary Medical Association · 2025

DOI: 10.2460/javma.24.04.0271 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the American Veterinary Medical Association, 2025. Verfasst von Curtis G Rheingold und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Peritonitis, Cat Diseases, Dog Diseases. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 33 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To evaluate whether abdominal ultrasound correctly diagnosed septic peritonitis and correctly identified its causative lesion in dogs and cats. ANIMALS 84 client-owned dogs and 10 cats that underwent an abdominal ultrasound and had confirmation of septic peritonitis via exploratory laparotomy or necropsy. METHODS This retrospective case series documented abdominal ultrasound findings, surgical or necropsy findings, and method for initial diagnosis of septic peritonitis, if different from surgery or necropsy. The surgical report and necropsy findings were compared to sonography results to confirm a diagnosis of septic peritonitis. The frequency at which sonography diagnosed septic peritonitis and its causative lesion was calculated for each type of lesion pathology and organ system. Secondary aims included evaluating the effect of patient characteristics (body weight and species) on sonographic results and whether lesion type or location affected mortality. RESULTS Most lesions causing septic peritonitis (70.2%) were gastrointestinal in origin and were nonneoplastic ulcerations or perforations (50%). Abdominal ultrasound diagnosed 56.3% of cases of subsequently confirmed septic peritonitis and correctly identified 67% of the causative lesions. Lesions of the gastrointestinal tract and ulcerations/perforations were the most frequent correct sonographic diagnoses and most likely to lead to a correct sonographic diagnosis of septic peritonitis. Lesions located in the hepatobiliary system and lesion types other than neoplasia or ulcerations/perforations were the most frequently missed by abdominal ultrasound. CLINICAL RELEVANCE Abdominal ultrasound often fails to diagnose septic peritonitis or the underlying causative lesion, and its accuracy depends on the affected organ and type of lesion.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

PeritonitisCat DiseasesDog DiseasesAnimalsCatsDogsRetrospective StudiesUltrasonographyMaleFemaleAutopsyAbdomen

Stichwörter der Autor:innen

abdominal ultrasoundexploratory laparotomysepsisseptic peritonitisultrasound

Autor:innen und Institutionen

ORCID-Profile: Anna Tran

Zitieren

APA

Rheingold, C. G., Dickens, C., Tran, A., Hess, R. S., & Buriko, Y. (2025). Abdominal ultrasound has inconsistent agreement with subsequent surgery or necropsy findings in dogs and cats with septic peritonitis. Journal of the American Veterinary Medical Association. https://doi.org/10.2460/javma.24.04.0271

Vancouver

Rheingold CG, Dickens C, Tran A, Hess RS, Buriko Y. Abdominal ultrasound has inconsistent agreement with subsequent surgery or necropsy findings in dogs and cats with septic peritonitis. Journal of the American Veterinary Medical Association. 2025. doi:10.2460/javma.24.04.0271

BibTeX
@article{Rheingold2025,
  author = {Rheingold, Curtis G and Dickens, Cody and Tran, Anna and Hess, Rebecka S and Buriko, Yekaterina},
  title = {Abdominal ultrasound has inconsistent agreement with subsequent surgery or necropsy findings in dogs and cats with septic peritonitis},
  journal = {Journal of the American Veterinary Medical Association},
  year = {2025},
  doi = {10.2460/javma.24.04.0271}
}
Kostenlos starten →