Refractive error of canine cataract patients following implantation with three types of intraocular lenses
Journal of the American Veterinary Medical Association · 2024
DOI: 10.2460/javma.23.08.0445 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the American Veterinary Medical Association, 2024. Verfasst von Mihal Kaminsky und 4 weiteren Autor:innen. Beteiligte Einrichtung: 1Eye Care for Animals, Pasadena, CA. Hauptthemen laut MEDLINE: Cataract, Dog Diseases, Lenses, Intraocular, Phacoemulsification. Die Arbeit nennt 25 Literaturangaben.
Abstract (Originalsprache)
OBJECTIVE To evaluate refractive state outcomes following phacoemulsification and implantation of 3 different intraocular lenses (IOLs). ANIMALS A prospective, randomized, controlled study was conducted on 43 client-owned dogs undergoing phacoemulsification with IOL implantation. METHODS Eyes were randomized to receive either an-vision Fo-X (n = 26), an-vision MD8 (18), or I-MED I-LENS (24) IOL. Refraction was measured 1 week, 1 month, and 3 months postoperatively using streak retinoscopy by 2 examiners masked to each other’s results. RESULTS Postoperative refractive outcomes were highly correlated and not significantly different between 2 examiners for all time points ( r = 0.97, 0.98, and 1.00; P = .76, .94, and .98, respectively). One week postoperatively, the refractive errors (mean ± SD) for Fo-X, MD8, and I-LENS were –0.14 ± 2.02 diopters (D), 0.97 ± 2.01 D, and 0.15 ± 2.55 D, respectively. One month postoperatively, the refractive errors were 0.35 ± 2.04 D, 0.06 ± 2.41 D, and –0.82 ± 2.20 D, respectively. Three months postoperatively, the refractive errors were –0.16 ± 2.67 D, 1.60 ± 2.99 D, and 0.59 ± 1.51 D, respectively. There were no significant differences in refractive error outcomes between Fo-X, MD8, and I-LENS at 1 week, 1 month, and 3 months postoperatively ( P = .16; F (df=2,66)- = 1.89). However, the Fo-X was the only IOL to yield nearly emmetropic outcomes (±0.50 D) at all 3 time points. CLINICAL RELEVANCE The postoperative refractive states of dogs were not statistically different when comparing 3 types of IOLs at 3 postoperative time points, though the Fo-X was the only IOL to yield nearly emmetropic outcomes at all 3 time points.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- 1Eye Care for Animals, Pasadena, CA.
- 2Koret School of Veterinary Medicine, Hebrew University of Jerusalem, Israel.
- 3Department of Optometry and Vision Science, Hadassah Academic College Jerusalem, Israel.
Zitieren
APA
Kaminsky, M., Hoffman, A., Ofri, R., Konrade, K., & Gantz, L. (2024). Refractive error of canine cataract patients following implantation with three types of intraocular lenses. Journal of the American Veterinary Medical Association. https://doi.org/10.2460/javma.23.08.0445
Vancouver
Kaminsky M, Hoffman A, Ofri R, Konrade K, Gantz L. Refractive error of canine cataract patients following implantation with three types of intraocular lenses. Journal of the American Veterinary Medical Association. 2024. doi:10.2460/javma.23.08.0445
BibTeX
@article{Kaminsky2024,
author = {Kaminsky, Mihal and Hoffman, Allison and Ofri, Ron and Konrade, Kricket and Gantz, Liat},
title = {Refractive error of canine cataract patients following implantation with three types of intraocular lenses},
journal = {Journal of the American Veterinary Medical Association},
year = {2024},
doi = {10.2460/javma.23.08.0445}
}
EUVIMED