Use of an automated endoscopic suturing device does not improve mental workload or time of intracorporeal suturing among surgical residents
American Journal of Veterinary Research · 01.11.2026 · 87 (11)
DOI: 10.2460/ajvr.26.04.0173 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 01.11.2026. Verfasst von Francesca P Solari und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL. Hauptthemen laut MEDLINE: Suture Techniques, Internship and Residency, Endoscopy, Workload. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To compare 2 intracorporeal suturing techniques among surgical residents.
Methods
Surgical residents at an academic teaching hospital were invited to participate. All participants completed 2 intracorporeal suturing trials in a laparoscopic trainer using either endoscopic needle drivers (END) or an automated endoscopic suturing device (ESD), with 14 days between trials. A standardized, descriptive video of each intracorporeal suturing technique was provided 7 days before the respective trial. Time to perform suturing was recorded, and participants completed a National Aeronautics and Space Administration Task Load Index (NASA-TLX) questionnaire following each trial. Suture lines were subjectively blindly scored using a standardized questionnaire by 3 surgeons.
Results
10 surgical residents across 4 years of training were enrolled. Mean time to complete the suturing trial was 5.72 ± 1.49 minutes for END and 6.00 ±2.14 minutes for ESD ( P = .76). The mean NASA-TLX score was 44.60 ± 19.02 for END and 44.33 ± 22.22 for ESD ( P = .83). Median suture evaluation score was 11 (IQR, 8 to 11) for END and 11 (IQR, 9 to 11) for ESD ( P = .13). Mean time to perform suturing was significantly different across years of training in residency for both ESD and END ( P = .006).
Conclusions
In this ex vivo model, an automated ESD provided no benefit for ease of performing intracorporeal suturing among surgical residents. Clinical Relevance Surgical residents can perform intracorporeal suturing with knotless barbed suture using either ESD or END. Further evaluation of the learning curve of each instrument for novice surgeons is warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Small Animal Clinical Sciences, College of Veterinary Medicine, University of Florida, Gainesville, FL.
- Institute of Farm and Agricultural Sciences, Statistics Consulting Unit, University of Florida, Gainesville, FL.
ORCID-Profile: Francesca P Solari
Zitieren
APA
Solari, F. P., Williams, R. W., Case, J. B., Ham, K., & Colee, J. C. (2026). Use of an automated endoscopic suturing device does not improve mental workload or time of intracorporeal suturing among surgical residents. American Journal of Veterinary Research, 87(11). https://doi.org/10.2460/ajvr.26.04.0173
Vancouver
Solari FP, Williams RW, Case JB, Ham K, Colee JC. Use of an automated endoscopic suturing device does not improve mental workload or time of intracorporeal suturing among surgical residents. American Journal of Veterinary Research. 2026;87(11). doi:10.2460/ajvr.26.04.0173
BibTeX
@article{Solari2026,
author = {Solari, Francesca P and Williams, Rachel W and Case, J Brad and Ham, Kathleen and Colee, James C},
title = {Use of an automated endoscopic suturing device does not improve mental workload or time of intracorporeal suturing among surgical residents},
journal = {American Journal of Veterinary Research},
year = {2026},
volume = {87},
number = {11},
doi = {10.2460/ajvr.26.04.0173}
}
EUVIMED