EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Needle bevel orientation does not affect the cranial spread of injectate in a lumbosacral epidural in canine cadavers

Olivia Harris, Tatiana Henriques Ferreira iD, Samantha Loeber iD, Sarah Hughes, Kyle J Bartholomew iD

American Journal of Veterinary Research · 01.11.2026 · 87 (11)

DOI: 10.2460/ajvr.26.03.0124 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 01.11.2026. Verfasst von Olivia Harris und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Contrast Media, Iohexol. Die Arbeit nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To investigate the cranial and circumferential spread of iohexol (240 mg/mL) diluted 1:3 with saline injected at the lumbosacral junction in canine cadavers using 0.1- and 0.2-mL/kg volumes administered with a cranial- or caudal-facing Tuohy bevel direction.

Methods

Lumbosacral epidurals were performed with a cranial- or caudal-facing needle bevel. The median vertebrae reached and the estimated percentage of the spinal cord surrounded with injectate were assessed via CT after administering two 0.1-mL/kg aliquots of injectate. Contrast medium was diluted to achieve physical properties closer to local anesthetics.

Results

5 cadavers in each group were assessed in August of 2024. The median vertebrae reached with a 0.1-mL/kg volume using a cranial bevel and 100%, ≥ 50%, and ≥ 1% circumferential epidural coverage contrast medium were 1, 7, and 10 bodies compared to a caudal bevel direction of 1, 7, and 9 bodies. For 0.2-mL/kg total volume using a cranial bevel and having 100%, ≥ 50%, and ≥ 1% circumferential epidural coverage, there were 2, 9, and 14 bodies compared to a caudal bevel direction being 2, 11, and 15 bodies.

Conclusions

The findings in this cadaveric study suggest that needle bevel direction does not affect the cranial epidural spread of injectate performed at the lumbosacral space. Clinical Relevance While no benefit to performing a lumbosacral epidural with a caudally facing bevel in limiting cranial spread was found, further studies in live patients are required to adjust clinical recommendations.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaIohexolAnimalsDogsCadaverInjections, EpiduralLumbosacral RegionEpidural Space

Stichwörter der Autor:innen

caninecranial spreadepidurallumbosacralneedle bevel orientation

Substanzen

Contrast MediaIohexol

Autor:innen und Institutionen

ORCID-Profile: Tatiana Henriques Ferreira, Samantha Loeber, Kyle J Bartholomew

Zitieren

APA

Harris, O., Ferreira, T. H., Loeber, S., Hughes, S., & Bartholomew, K. J. (2026). Needle bevel orientation does not affect the cranial spread of injectate in a lumbosacral epidural in canine cadavers. American Journal of Veterinary Research, 87(11). https://doi.org/10.2460/ajvr.26.03.0124

Vancouver

Harris O, Ferreira TH, Loeber S, Hughes S, Bartholomew KJ. Needle bevel orientation does not affect the cranial spread of injectate in a lumbosacral epidural in canine cadavers. American Journal of Veterinary Research. 2026;87(11). doi:10.2460/ajvr.26.03.0124

BibTeX
@article{Harris2026,
  author = {Harris, Olivia and Ferreira, Tatiana Henriques and Loeber, Samantha and Hughes, Sarah and Bartholomew, Kyle J},
  title = {Needle bevel orientation does not affect the cranial spread of injectate in a lumbosacral epidural in canine cadavers},
  journal = {American Journal of Veterinary Research},
  year = {2026},
  volume = {87},
  number = {11},
  doi = {10.2460/ajvr.26.03.0124}
}
Kostenlos starten →