Macroscale and microscale mechanical and biochemical properties of the equine superficial digital flexor tendon are regionally dependent
American Journal of Veterinary Research · 01.08.2026 · 87 (8)
DOI: 10.2460/ajvr.26.02.0059 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 01.08.2026. Verfasst von Samantha L Watson und 6 weiteren Autor:innen. Beteiligte Einrichtung: Lampe Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC. Hauptthemen laut MEDLINE: Tendons. Die Arbeit nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: NIH HHS.
Abstract (Originalsprache)
Objective
To examine regional mechanical and biochemical differences across the length of the equine superficial digital flexor tendon (SDFT).
Methods
Equine SDFTs were collected postmortem from 9 donors and divided into proximal, middle, and distal regions based on the location of the musculotendinous and osteotendinous junctions. Tensile testing was performed on samples to obtain macroscale mechanical properties, and atomic force microscopy was done to obtain microscale mechanical properties. Biochemical assays and histological staining were done to assess glycosaminoglycan (GAG), collagen, and DNA content in each region.
Results
Regional differences were present in macroscale mechanical properties and biochemical properties. Differences were primarily seen between the middle and distal region, with the distal region having a 3-fold increased GAG content (Δ14.15 µg GAG/mg sample; 95% CI, −0.32 to 28.62) and a 1.67-fold decreased macroscopic tensile modulus (Δ−68.2 MPa; 95% CI, −107.9 to −28.5). A more disorganized collagen fibril matrix was seen in the distal region through histological staining.
Conclusions
Mechanical, biochemical, and histological regional differences exist with the equine SDFT. In particular, the distal region showed a disorganized matrix with higher GAG content and decreased modulus in comparison to the proximal and middle regions. Clinical Relevance Our data provide information that helps better understand normal SDFT function and presentation of tendinopathy by providing regional structural and biochemical and mechanical information within the SDFT.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Lampe Joint Department of Biomedical Engineering, North Carolina State University and University of North Carolina at Chapel Hill, Raleigh, NC.
- Comparative Medicine Institute, North Carolina State University, Raleigh, NC.
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, Raleigh, NC.
- Department of Orthopaedics, UNC School of Medicine, University of North Carolina at Chapel Hill, Chapel Hill, NC.
ORCID-Profile: Samantha L Watson, Drew W Koch, Shannon S Connard, Ashley C Brown, Lauren V Schnabel, Matthew B Fisher
Förderung
- NIH HHS
Zitieren
APA
Watson, S. L., Davis, Z. G., Koch, D. W., Connard, S. S., Brown, A. C., Schnabel, L. V., & Fisher, M. B. (2026). Macroscale and microscale mechanical and biochemical properties of the equine superficial digital flexor tendon are regionally dependent. American Journal of Veterinary Research, 87(8). https://doi.org/10.2460/ajvr.26.02.0059
Vancouver
Watson SL, Davis ZG, Koch DW, Connard SS, Brown AC, Schnabel LV, et al. Macroscale and microscale mechanical and biochemical properties of the equine superficial digital flexor tendon are regionally dependent. American Journal of Veterinary Research. 2026;87(8). doi:10.2460/ajvr.26.02.0059
BibTeX
@article{Watson2026,
author = {Watson, Samantha L and Davis, Zachary G and Koch, Drew W and Connard, Shannon S and Brown, Ashley C and Schnabel, Lauren V and Fisher, Matthew B},
title = {Macroscale and microscale mechanical and biochemical properties of the equine superficial digital flexor tendon are regionally dependent},
journal = {American Journal of Veterinary Research},
year = {2026},
volume = {87},
number = {8},
doi = {10.2460/ajvr.26.02.0059}
}