Feasibility of a hand-held myotonometry device for measuring biomechanical muscle parameters in horses
American Journal of Veterinary Research · 01.08.2026 · 87 (8)
DOI: 10.2460/ajvr.26.02.0050 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, erschienen am 01.08.2026. Verfasst von Gesiane Ribeiro und 6 weiteren Autor:innen. Beteiligte Einrichtung: Research in Veterinary Medicine (I-MVET), Faculty of Veterinary Medicine, Lusófona University, Lisbon, Portugal. Hauptthemen laut MEDLINE: Muscle, Skeletal. Die Arbeit nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To evaluate the feasibility of a hand-held myotometry device for measuring the biomechanical parameters (frequency, stiffness, and decrement) of the longissimus dorsi muscle in the thoracolumbar region of healthy horses.
Methods
Data were obtained from 50 adult horses. The biomechanical parameters were measured using a MyotonPRO device in triple-scan mode. Measurements were recorded on both sides, with the horses standing square. The analysis focused on whether there were differences between the sides and correlations between the variables.
Results
The mean muscle frequency (hertz) was 21.66 ± 2.88 on the left side and 21.45 ± 2.75 on the right side. The mean stiffness (N/m) was 535.94 ± 82.87 on the left side and 525.41 ± 75.15 on the right side. The mean decrement on the left was 1.68 ± 0.34, and the mean decrement on the right was 1.71 ± 0.26. There were no significant differences between the sides for any parameter, indicating symmetry between them. On the left side, correlations were found between biomechanical parameters and age and body score.
Conclusions
The MyotonPRO device is a tool that can be used to measure muscle tone, stiffness, and decrement in horses. Clinical Relevance Validating a portable tool for measuring biomechanical parameters can make muscle assessment in horses more objective and contribute to diagnosis as well as injury prevention and recovery monitoring.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Research in Veterinary Medicine (I-MVET), Faculty of Veterinary Medicine, Lusófona University, Lisbon, Portugal.
- Animal and Veterinary Science Centre (CECAV), Faculty of Veterinary Medicine, Lusófona University, Lisbon, Portugal.
- Centre for Interdisciplinary Research in Animal Health (CIISA), Faculty of Veterinary Medicine, University of Lisbon, Lisbon, Portugal.
- Faculty of Veterinary Medicine, Lusófona University, Lisbon, Portugal.
- Centre for Statistics and Applications (CEAUL), Faculty of Sciences, University of Lisbon, Lisbon, Portugal.
- Centre for Transdisciplinary Studies for Development (CETRAD-Europeia HUB), Faculty of Social Sciences and Technology, Universidade Europeia, Lisbon, Portugal.
Zitieren
APA
Ribeiro, G., Agrícola, R., Sanchez, M. M. F., Ramos, F. R., Borges, J., Abrantes, J., & Prazeres, J. (2026). Feasibility of a hand-held myotonometry device for measuring biomechanical muscle parameters in horses. American Journal of Veterinary Research, 87(8). https://doi.org/10.2460/ajvr.26.02.0050
Vancouver
Ribeiro G, Agrícola R, Sanchez MMF, Ramos FR, Borges J, Abrantes J, et al. Feasibility of a hand-held myotonometry device for measuring biomechanical muscle parameters in horses. American Journal of Veterinary Research. 2026;87(8). doi:10.2460/ajvr.26.02.0050
BibTeX
@article{Ribeiro2026,
author = {Ribeiro, Gesiane and Agrícola, Ricardo and Sanchez, Maria Margarida Formosinho and Ramos, Filipe R and Borges, João and Abrantes, João and Prazeres, José},
title = {Feasibility of a hand-held myotonometry device for measuring biomechanical muscle parameters in horses},
journal = {American Journal of Veterinary Research},
year = {2026},
volume = {87},
number = {8},
doi = {10.2460/ajvr.26.02.0050}
}
EUVIMED