Manubrium tracheal index versus thoracic inlet tracheal index and proximal rib3 tracheal score to radiographically assess bulldogs’ tracheal diameter at 3 levels
American Journal of Veterinary Research · 2025
DOI: 10.2460/ajvr.24.12.0400 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2025. Verfasst von Ayman A Mostafa und 1 weiteren Autor:innen. Beteiligte Einrichtung: Department of Small Animal Surgery and Radiology, Faculty of Veterinary Medicine, Cairo University, Giza, Egypt. Hauptthemen laut MEDLINE: Trachea, Radiography, Thoracic, Ribs. Die Arbeit nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Objective
To evaluate the manubrium tracheal index (M-TI) at 3 levels and the correlation between M-TI and other conventional techniques.
Methods
Medical records and thoracic radiographs of healthy bulldogs were investigated. Tracheal luminal diameter (TLD) was measured at the caudal cervical, thoracic inlet, and intrathoracic tracheal regions on right lateral thoracic view. The absolute and average TLDs were standardized by the manubrium length (ML), thoracic inlet distance (Ti-D), and proximal third rib width to calculate M-TI, thoracic inlet tracheal index (Ti-TI), and proximal rib3 tracheal score (PR3-TS), respectively. Correlations between averaged tracheal diameter and each of ML, Ti-D, and proximal third rib width and between M-TI and each of Ti-TI and PR3-TS were evaluated.
Results
100 healthy French (n = 34), English (n = 33), and American (n = 33) Bulldogs met the inclusion criteria. The narrowest tracheal diameter was identified at the thoracic inlet, which was significantly narrower than both the caudal cervical and intrathoracic tracheal regions. There was no significant difference between the caudal cervical and intrathoracic tracheal regions. Strong, positive, linear correlations were identified between TLD and each normalizing parameter (ie, ML, Ti-D, and PR3-TS). Weak-to-moderate correlations were identified between the 3 procedures (ie, M-TI, Ti-TI, and PR3-TS).
Conclusions
M-TI could be an alternative to Ti-TI and PR3-TS for monitoring TLD in bulldogs. Therefore, future screening for tracheal hypoplasia is recommended using M-TI. Clinical Relevance Bulldogs with M-TI < 0.29 at the thoracic inlet trachea and < 0.33 at the caudal cervical and intrathoracic trachea (average M-TI < 0.32) may have tracheal hypoplasia. However, further assessments of diseased bulldogs and the repeatability of measurements are still warranted.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Small Animal Surgery and Radiology, Faculty of Veterinary Medicine, Cairo University, Giza, Egypt.
- Department of Veterinary Clinical Sciences, College of Veterinary Medicine, Western University of Health Sciences, Pomona, CA.
- Bailey Small Animal Teaching Hospital, Department of Clinical Sciences, College of Veterinary Medicine, Auburn University, Auburn, AL.
ORCID-Profile: Ayman A Mostafa, Clifford R Berry
Zitieren
APA
Mostafa, A. A., & Berry, C. R. (2025). Manubrium tracheal index versus thoracic inlet tracheal index and proximal rib3 tracheal score to radiographically assess bulldogs’ tracheal diameter at 3 levels. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.12.0400
Vancouver
Mostafa AA, Berry CR. Manubrium tracheal index versus thoracic inlet tracheal index and proximal rib3 tracheal score to radiographically assess bulldogs’ tracheal diameter at 3 levels. American Journal of Veterinary Research. 2025. doi:10.2460/ajvr.24.12.0400
BibTeX
@article{Mostafa2025,
author = {Mostafa, Ayman A and Berry, Clifford R},
title = {Manubrium tracheal index versus thoracic inlet tracheal index and proximal rib3 tracheal score to radiographically assess bulldogs’ tracheal diameter at 3 levels},
journal = {American Journal of Veterinary Research},
year = {2025},
doi = {10.2460/ajvr.24.12.0400}
}
EUVIMED