Finite element analysis shows minimal stability difference between individualized mini-hemilaminectomy–corpectomy and partial lateral corpectomy in a dog model
American Journal of Veterinary Research · 2024
DOI: 10.2460/ajvr.24.08.0244 ↗Kurz gefasst
Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2024. Verfasst von Yuki Kikuchi und 4 weiteren Autor:innen. Beteiligte Einrichtung: Laboratory of the Veterinary Surgery, Nippon Veterinary and Life Science University, Musashino, Japan. Hauptthemen laut MEDLINE: Laminectomy, Finite Element Analysis. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 47 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
OBJECTIVE Use finite element analysis to evaluate the biomechanical effects of spinal decompression procedures in healthy Beagle dogs, comparing individualized mini-hemilaminectomy–corpectomy (iMHC), mini-hemilaminectomy, partial lateral corpectomy (PLC), and hemilaminectomy. METHODS A finite element model of the L1-L2 functional spinal unit was generated using CT data. For each decompression model, loads were applied in 0.2-Nm steps (maximum, 2.0 Nm) in 6 directions: flexion, extension, right and left lateral bending, and right and left axial rotation. The L1 spinous process tip displacement angle was quantified numerically. RESULTS Among the 4 techniques, mini-hemilaminectomy exhibited the smallest displacement angles across all directions. Hemilaminectomy exhibited the largest displacement angles in extension, flexion, right rotation, and left rotation across all techniques. Left and right lateral bending displacement angles were marginally larger for iMHC than for hemilaminectomy at 0.4 Nm; however, at 2.0 Nm, displacement angles were similar. CONCLUSIONS Mini-hemilaminectomy minimizes functional spinal unit instability to the greatest extent. Hemilaminectomy is more unstable than iMHC and PLC in flexion, extension, and rotation. Mini-hemilaminectomy–corpectomy and PLC are more unstable than hemilaminectomy in lateral bending, with iMHC being slightly more unstable than PLC or nearly equal. CLINICAL RELEVANCE Mini-hemilaminectomy minimizes instability to the greatest extent in cases of ventrolateral spinal compression. In cases of ventral spinal compression, iMHC may be preferable to PLC for providing equivalent stability without impeding spinal cord visualization, but both techniques can cause instability depending on loading direction, so careful attention to postoperative instability is necessary when excessive vertebral body resection is involved.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Laboratory of the Veterinary Surgery, Nippon Veterinary and Life Science University, Musashino, Japan.
- YPC Tokyo Animal Orthopedic Surgery Hospital, Kouto-ku, Japan.
- Laboratory of Small Animal Surgery 1, School of Veterinary Medicine, Kitasato University, Towada, Japan.
ORCID-Profile: Masakazu Shimada
Zitieren
APA
Kikuchi, Y., Shimada, M., Takahashi, F., Yamaguchi, S., & Hara, Y. (2024). Finite element analysis shows minimal stability difference between individualized mini-hemilaminectomy–corpectomy and partial lateral corpectomy in a dog model. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.24.08.0244
Vancouver
Kikuchi Y, Shimada M, Takahashi F, Yamaguchi S, Hara Y. Finite element analysis shows minimal stability difference between individualized mini-hemilaminectomy–corpectomy and partial lateral corpectomy in a dog model. American Journal of Veterinary Research. 2024. doi:10.2460/ajvr.24.08.0244
BibTeX
@article{Kikuchi2024,
author = {Kikuchi, Yuki and Shimada, Masakazu and Takahashi, Fumitaka and Yamaguchi, Shinya and Hara, Yasushi},
title = {Finite element analysis shows minimal stability difference between individualized mini-hemilaminectomy–corpectomy and partial lateral corpectomy in a dog model},
journal = {American Journal of Veterinary Research},
year = {2024},
doi = {10.2460/ajvr.24.08.0244}
}
EUVIMED