EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Effect of volume and methylene blue on fluorescence intensity and transit of indocyanine green for sentinel lymph node mapping in a simulated feline tumor model

Hui Yu Lu, Charly McKenna, Ann Ram, Michelle L Oblak

American Journal of Veterinary Research · 2023

DOI: 10.2460/ajvr.23.07.0168 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2023. Verfasst von Hui Yu Lu und 3 weiteren Autor:innen. Beteiligte Einrichtung: Toronto Animal Health Partners Specialty and Emergency Hospital, North York, ON, Canada. Hauptthemen laut MEDLINE: Indocyanine Green, Sentinel Lymph Node. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To compare the effect of volume and solution on transit time and fluorescence intensity (FI) using near-infrared fluorescence imaging (NIRF) in a simulated tumor model in cats. Secondarily, to describe SLN mapping with indocyanine green (ICG) NIRF and report any adverse effects of intradermally injected ICG in cats. ANIMALS 7 healthy purpose-bred domestic shorthaired male cats. METHODS Cats were randomly divided into 2 groups (ICG or ICG + methylene blue [MB]). Transit time and FI were determined for 1 or 2 mL solutions injected intradermally in 4 quadrants around a simulated tumor. Following massage, fluorescence intensity was quantified by calculating the corrected total ROI fluorescence using ImageJ software. Cats were monitored for adverse effects up to 4 weeks post-injection. RESULTS A larger solution volume had decreased transit times to the SLN ( P = .001). There was no significant difference in transit times between ICG and ICG-MB. ICG demonstrated a greater FI ( P = .001) in the SLN compared to ICG-MB. Methylene blue did not percutaneously fluoresce under NIRF. The volume of the solution did not significantly affect FI. No adverse reactions were reported. CLINICAL RELEVANCE Increased volume of ICG may aid in rapid percutaneous lymphatic tracking from tumor to SLN. Indocyanine green alone may be preferred over ICG-MB for greater visualization of the SLN. Intradermal injections of ICG and ICG-MB were well-tolerated in healthy cats with no significant complications. Clinical evaluation of this technique in an impaired lymphatic system, as seen in cancer patients, should be assessed in future research.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Indocyanine GreenSentinel Lymph NodeCatsMaleAnimalsSentinel Lymph Node BiopsyColoring AgentsMethylene BlueLymph Nodes

Stichwörter der Autor:innen

indocyanine greenlymph node mappingmethylene bluesentinel lymph nodetransit time

Substanzen

Indocyanine GreenColoring AgentsMethylene Blue

Autor:innen und Institutionen

  • Toronto Animal Health Partners Specialty and Emergency Hospital, North York, ON, Canada.
  • Ontario Veterinary College, University of Guelph, Guelph, ON, Canada.

Zitieren

APA

Lu, H. Y., McKenna, C., Ram, A., & Oblak, M. L. (2023). Effect of volume and methylene blue on fluorescence intensity and transit of indocyanine green for sentinel lymph node mapping in a simulated feline tumor model. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.23.07.0168

Vancouver

Lu HY, McKenna C, Ram A, Oblak ML. Effect of volume and methylene blue on fluorescence intensity and transit of indocyanine green for sentinel lymph node mapping in a simulated feline tumor model. American Journal of Veterinary Research. 2023. doi:10.2460/ajvr.23.07.0168

BibTeX
@article{Lu2023,
  author = {Lu, Hui Yu and McKenna, Charly and Ram, Ann and Oblak, Michelle L},
  title = {Effect of volume and methylene blue on fluorescence intensity and transit of indocyanine green for sentinel lymph node mapping in a simulated feline tumor model},
  journal = {American Journal of Veterinary Research},
  year = {2023},
  doi = {10.2460/ajvr.23.07.0168}
}
Kostenlos starten →