EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses

Dario Floriano, Emma Gorenberg, Amanda Watkins, Klaus Hopster

American Journal of Veterinary Research · 2023

DOI: 10.2460/ajvr.23.07.0166 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2023. Verfasst von Dario Floriano und 3 weiteren Autor:innen. Hauptthemen laut MEDLINE: Analgesia, Epidural, Xylazine. Die Arbeit nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To test the influence of increasing injectate volumes on the regional effects of xylazine and morphine epidural analgesia, with the hypothesis that increasing volume produces more cranial spread of analgesia as determined by thermal threshold (TT) testing. ANIMALS 6 university-owned research/teaching horses (2 mares, 4 geldings) deemed healthy on physical examination and basic lameness evaluation, aged 6–19 years and weighing 420–560 kg, were used in this prospective, randomized, blinded, cross-over experimental study. METHODS After routine placement of a caudal epidural catheter, all animals were subsequently instrumented with a TT testing system at the withers (Location A), the cranial (Location B), and caudal (Location C) abdominal area, over the tuber coxae (Location D), and the hind limb dorsal pasterns (Location E). All horses underwent five testing cycles with 0.2 mg/kg morphine and 0.2 mg/kg xylazine diluted to 20, 35, 50, 75, and 100 mL. TT testing was performed at 2, 4, 6, 8, and 10 hours by blinded investigators. RESULTS With increased epidural volume, significantly greater cranial spread of analgesic effect was noted. All epidural volumes caused significant changes in TT testing at location E but only the largest volume resulted in a significant TT testing change at location A. CLINICAL RELEVANCE Volume influences the regional effects of caudal epidural analgesia in horses but might affect analgesic reliability.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Analgesia, EpiduralXylazineAnimalsFemaleMaleAnalgesicsCathetersCross-Over StudiesDouble-Blind MethodHorsesMorphinePainProspective StudiesReproducibility of Results

Stichwörter der Autor:innen

epidural anesthesiaepidural xylazine morphineregional anesthesia and analgesiathermal nociceptive threshold testingthoracic limb analgesia

Substanzen

AnalgesicsMorphineXylazine

Zitieren

APA

Floriano, D., Gorenberg, E., Watkins, A., & Hopster, K. (2023). The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.23.07.0166

Vancouver

Floriano D, Gorenberg E, Watkins A, Hopster K. The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses. American Journal of Veterinary Research. 2023. doi:10.2460/ajvr.23.07.0166

BibTeX
@article{Floriano2023,
  author = {Floriano, Dario and Gorenberg, Emma and Watkins, Amanda and Hopster, Klaus},
  title = {The dilutional volume of morphine and xylazine administered via caudal epidural catheter affects cranial spread of analgesia in healthy standing horses},
  journal = {American Journal of Veterinary Research},
  year = {2023},
  doi = {10.2460/ajvr.23.07.0166}
}
Kostenlos starten →