EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Large animal ventilator-integrated volumetric capnography generates clinically acceptable values of physiologic dead space in anesthetized healthy adult horses

Alycia Frampton, Dario Floriano, Keith Simpson, Klaus Hopster

American Journal of Veterinary Research · 2024

DOI: 10.2460/ajvr.23.05.0107 ↗

Kurz gefasst

Fachartikel in der Zeitschrift American Journal of Veterinary Research, 2024. Verfasst von Alycia Frampton und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Studies - New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA. Hauptthemen laut MEDLINE: Capnography, Carbon Dioxide. Die Arbeit nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVE To evaluate the agreement between the Tafonius large animal ventilator-integrated volumetric capnography (vCap) software and the Respironics NICO noninvasive cardiac output monitor reference system. ANIMALS Data were collected from 56 healthy adult horses undergoing general anesthesia. METHODS Animals were placed under general anesthesia and connected to the Tafonius large animal ventilator circle system. A flow partitioning device with CO 2 and flow sensors was utilized to couple the endotracheal tube to the NICO monitor. Tafonius CO 2 and flow sensors are incorporated into the Y-piece of the breathing circuit. Arterial blood samples were collected to determine the partial pressure of arterial carbon dioxide (PaCO 2 ) immediately before data collection. The PaCO 2 was input into the Tafonius and NICO monitor, and dead space ventilation (%V d ), end-tidal CO 2 partial pressure (ET co 2 ), mixed-expired CO 2 partial pressure (P eco 2 ), and expired tidal volume (V t ) were calculated over a single breath. Multiple measurements were completed for each patient, with a total of 200 paired data points collected for analysis. Data were assessed for normality, and Bland-Altman analysis was performed. Bias and 95% limits of agreement were calculated. RESULTS The limits of agreement for %V d of the ventilator-derived measurements fell within ± 10% of the NICO monitor reference method. CLINICAL RELEVANCE Our results indicate that, when compared to the NICO monitor method, the Tafonius-integrated vCap software provides clinically acceptable values of P eco 2 , V t , and %V d in healthy adult horses.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CapnographyCarbon DioxideHorsesAnimalsRespiratory Dead SpaceTidal VolumeRespiration, ArtificialVentilators, Mechanical

Stichwörter der Autor:innen

dead spaceequine anesthesialarge animal ventilatorrespiratory physiologyvolumetric capnography

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Department of Clinical Studies - New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA.

Zitieren

APA

Frampton, A., Floriano, D., Simpson, K., & Hopster, K. (2024). Large animal ventilator-integrated volumetric capnography generates clinically acceptable values of physiologic dead space in anesthetized healthy adult horses. American Journal of Veterinary Research. https://doi.org/10.2460/ajvr.23.05.0107

Vancouver

Frampton A, Floriano D, Simpson K, Hopster K. Large animal ventilator-integrated volumetric capnography generates clinically acceptable values of physiologic dead space in anesthetized healthy adult horses. American Journal of Veterinary Research. 2024. doi:10.2460/ajvr.23.05.0107

BibTeX
@article{Frampton2024,
  author = {Frampton, Alycia and Floriano, Dario and Simpson, Keith and Hopster, Klaus},
  title = {Large animal ventilator-integrated volumetric capnography generates clinically acceptable values of physiologic dead space in anesthetized healthy adult horses},
  journal = {American Journal of Veterinary Research},
  year = {2024},
  doi = {10.2460/ajvr.23.05.0107}
}
Kostenlos starten →