Transapical Transcatheter Edge-to-Edge Repair (TEER) of the mitral valve using the V-Clamp system – A promising approach for minimally invasive cardiology in veterinary and experimental human medicine
Polish Journal of Veterinary Sciences · 17.03.2026 · 157-157
DOI: 10.24425/pjvs.2026.158510 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift Polish Journal of Veterinary Sciences, online erschienen am 17.03.2026. Verfasst von U Pasławska und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostics and Clinical Sciences, Institute of Veterinary Medicine, Nicolaus Copernicus University, Szosa Bydgoska 13, 87-100 Torun, P…. Hauptthemen laut MEDLINE: Mitral Valve, Dog Diseases, Mitral Valve Insufficiency, Minimally Invasive Surgical Procedures. Die Arbeit nennt 2 Literaturangaben.
Abstract (Originalsprache)
Mitral valve (MV) regurgitation (MVR) is mainly associated with mitral valve leaflet prolapse. The leading cause of MV leaflet prolapse is degeneration of the mitral valve leaflets or functional MVR. Until recently, there has been a scarcity of surgical options for minimally invasive mitral valve repair in dogs. In contrast, humans often have forms of MVR that do not qualify for conventional heart surgery or existing minimally invasive mitral valve repair methods. Transapical Transcatheter Edge-to-Edge Repair (TEER) of the MV is an innovative new method that uses special clips that are inserted into the heart through apical punctures. This technique enables effective closure of the defective valve without necessitating a traditional thoracotomy or opening the heart. It is the first minimally invasive method for valve clamping in dogs and a new option available for humans suffering from severe MVR. In this article, we summarize the knowledge of TEER and its use in humans and dogs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Diagnostics and Clinical Sciences, Institute of Veterinary Medicine, Nicolaus Copernicus University, Szosa Bydgoska 13, 87-100 Torun, Poland.
- Cardiovascular Research Foundation, Skirball Center for Innovation, 8 Corporate Drive, Orangeburg, New York, NY, USA.
- Department of Veterinary Surgery, Institute of Veterinary Medicine, Nicolaus Copernicus University, Szosa Bydgoska 13, 87-100 Torun, Poland.
Zitieren
APA
Pasławska, U., Grzeczka, A., Graczyk, S., Nowak, K., & Pasławski, R. (2026). Transapical Transcatheter Edge-to-Edge Repair (TEER) of the mitral valve using the V-Clamp system – A promising approach for minimally invasive cardiology in veterinary and experimental human medicine. Polish Journal of Veterinary Sciences, 157-157. https://doi.org/10.24425/pjvs.2026.158510
Vancouver
Pasławska U, Grzeczka A, Graczyk S, Nowak K, Pasławski R. Transapical Transcatheter Edge-to-Edge Repair (TEER) of the mitral valve using the V-Clamp system – A promising approach for minimally invasive cardiology in veterinary and experimental human medicine. Polish Journal of Veterinary Sciences. 2026:157-157. doi:10.24425/pjvs.2026.158510
BibTeX
@article{Pasawska2026,
author = {Pasławska, U and Grzeczka, A and Graczyk, S and Nowak, K and Pasławski, R},
title = {Transapical Transcatheter Edge-to-Edge Repair (TEER) of the mitral valve using the V-Clamp system – A promising approach for minimally invasive cardiology in veterinary and experimental human medicine},
journal = {Polish Journal of Veterinary Sciences},
year = {2026},
pages = {157--157},
doi = {10.24425/pjvs.2026.158510}
}
EUVIMED