The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body — a case report
Folia Medica Cracoviensia · 2024
DOI: 10.24425/fmc.2024.152175 ↗Kurz gefasst
Fallbericht in der Zeitschrift Folia Medica Cracoviensia, 2024. Verfasst von Mateusz Dworak und 5 weiteren Autor:innen. Beteiligte Einrichtung: Chair and Department of Otolaryngology, Jagiellonian University Medical College, Kraków, Poland. mateusz.dworak@uj.edu.pl. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Orbit, Eye Foreign Bodies, Wounds, Gunshot.
Abstract (Originalsprache)
Intraorbital foreign bodies still remain an unsolved and serious diagnostic problem. Due to the complicated anatomical orbital structure, both the diagnosis and treatment of these injuries are considered to be one of the most challenging. We present a case of a metallic foreign body (a bullet) imbeded in the orbit of a 10-year-old boy. Only after performing computed tomography imaging using the metal artifacts reduction algorithm it was possible to properly localize the foreign body. The issue of intraorbital foreign bodies is interdisciplinary and requires the co-operation between many specialists, including ophthalmologists, otorhinolaryngologists and radiologists.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Chair and Department of Otolaryngology, Jagiellonian University Medical College, Kraków, Poland. mateusz.dworak@uj.edu.pl.
- Chair and Department of Otolaryngology, Jagiellonian University Medical College, Kraków, Poland.
- Chair of Radiology, Jagiellonian University Medical College, Kraków, Poland.
Zitieren
APA
Dworak, M., Stolcman-Mrugała, K., Gałuszka, Z., Pasierb, K., Chrzan, R., & Składzień, J. (2024). The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body — a case report. Folia Medica Cracoviensia. https://doi.org/10.24425/fmc.2024.152175
Vancouver
Dworak M, Stolcman-Mrugała K, Gałuszka Z, Pasierb K, Chrzan R, Składzień J. The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body — a case report. Folia Medica Cracoviensia. 2024. doi:10.24425/fmc.2024.152175
BibTeX
@article{Dworak2024,
author = {Dworak, Mateusz and Stolcman-Mrugała, Kamila and Gałuszka, Zuzanna and Pasierb, Karolina and Chrzan, Robert and Składzień, Jacek},
title = {The usefulness of computed tomography with the reduction of metal artifacts in the location of an intraorbital foreign body — a case report},
journal = {Folia Medica Cracoviensia},
year = {2024},
doi = {10.24425/fmc.2024.152175}
}
EUVIMED