EUVIMEDEUVIMED entdecken
Crossref

A 3D model of the renal vasculature — a joined result of the corrosion casting technique, micro-CT imaging and rapid prototyping technology

Janusz Skrzat, Katarzyna Heryan, Jacek Tarasiuk, Sebastian Wroński, Klaudia Proniewska, Piotr Walecki, Michał Zarzecki, Grzegorz Goncerz, Jerzy Walocha

Folia Medica Cracoviensia · 2022

DOI: 10.24425/fmc.2021.140003 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Folia Medica Cracoviensia, 2022. Verfasst von Janusz Skrzat und 8 weiteren Autor:innen. Beteiligte Einrichtung: Jagiellonian University Medical College, Department of Anatomy, Kraków, Poland. j.skrzat@uj.edu.pl. Hauptthemen laut MEDLINE: Artifacts, Kidney. Die Arbeit nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Three-dimensional (3D) printed model of the renal vasculature shows a high level of accuracy of subsequent divisions of both the arterial and the venous tree. However, minor artifacts appeared in the form of oval endings to the terminal branches of the vascular tree, contrary to the anticipated sharply pointed segments. Unfortunately, selective laser sintering process does not currently permit to present the arterial, venous and urinary systems in distinct colors, hence topographic relationship between the vas-cular and the pelvicalyceal systems is difficult to attain. Nonetheless, the 3D printed model can be used for educational purposes to demonstrate the vast renal vasculature and may also serve as a reference model whilst evaluating morphological anomalies of the intrarenal vasculature in a surgical setting.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ArtifactsKidneyCorrosion CastingHumansImaging, Three-DimensionalTechnologyX-Ray Microtomography

Stichwörter der Autor:innen

corrosion castmicro-CTrapid prototypingrenal vasculature

Autor:innen und Institutionen

  • Jagiellonian University Medical College, Department of Anatomy, Kraków, Poland. j.skrzat@uj.edu.pl.
  • AGH University of Science and Technology, Department of Measurement and Electronics, Kraków, Poland.
  • AGH University of Science and Technology, Department of Condensed Matter Physics, Kraków, Poland.
  • Jagiellonian University Medical College, Department of Bioinformatics and Telemedicine, Kraków, Poland.
  • Jagiellonian University Medical College, Department of Anatomy, Kraków, Poland.

Zitieren

APA

Skrzat, J., Heryan, K., Tarasiuk, J., Wroński, S., Proniewska, K., Walecki, P., Zarzecki, M., Goncerz, G., & Walocha, J. (2022). A 3D model of the renal vasculature — a joined result of the corrosion casting technique, micro-CT imaging and rapid prototyping technology. Folia Medica Cracoviensia. https://doi.org/10.24425/fmc.2021.140003

Vancouver

Skrzat J, Heryan K, Tarasiuk J, Wroński S, Proniewska K, Walecki P, et al. A 3D model of the renal vasculature — a joined result of the corrosion casting technique, micro-CT imaging and rapid prototyping technology. Folia Medica Cracoviensia. 2022. doi:10.24425/fmc.2021.140003

BibTeX
@article{Skrzat2022,
  author = {Skrzat, Janusz and Heryan, Katarzyna and Tarasiuk, Jacek and Wroński, Sebastian and Proniewska, Klaudia and Walecki, Piotr and Zarzecki, Michał and Goncerz, Grzegorz and Walocha, Jerzy},
  title = {A 3D model of the renal vasculature — a joined result of the corrosion casting technique, micro-CT imaging and rapid prototyping technology},
  journal = {Folia Medica Cracoviensia},
  year = {2022},
  doi = {10.24425/fmc.2021.140003}
}
Kostenlos starten →