Parametric Analysis of Heat Transfer and Flow Characteristics of the Cross-Flow Heat Exchanger with a Backwards Splitter Plate Using the Computational Fluid Dynamics (CFD) Model

Sachin Kaushik, Subash Chandra Ram, Chandra Kishor, Sunil Chamoli

Archives of Thermodynamics · 23.04.2026 · 161-161

DOI: 10.24425/ather.2026.158667 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Thermodynamics, online erschienen am 23.04.2026. Verfasst von Sachin Kaushik und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This article investigates the parametric effects on heat transfer in cross-flow heat exchangers integrated with a backward splitter plate to enhance the coefficient of performance in a solar assisted vapour absorption refrigeration system. The system replaces conventional electric energy with solar energy, utilising a solar energy collector to heat water between 50 − 80°C. This heated water vaporises aqueous ammonia in a generator designed as a double pipe heat exchanger. The primary objective is to facilitate efficient heat transfer from the solar energy collector to the solar assisted vapour absorption refrigeration system and evaluate the cooling performance at varying water mass flow rates. Computational fluid dynamics has been used to solve the governing equations under appropriate boundary conditions. While second-order discretisation has been used for momen-tum and energy equations, coupled equations have been used to address velocity and pressure coupling. Convergence criteria of 10⁻⁶ for velocity and continuity, and 10⁻⁸ for energy, were employed. Thermal modelling was conducted to find out com-ponent-specific heat transfer rates and estimate the cumulative coefficient of performance. A small-capacity (1.5 ton or 5.25 kW) solar vapour absorption cooling system was tested. The study found that increasing the L/D ratio enhances heat transfer; for instance, at Re = 12000 and L/D = 2, the Nusselt number increased by 90% compared to Re = 2000. However, the pressure dropped significantly at L/D = 3, suggesting an optimal design trade-off. Additionally, the impact of key param-eters such as absorber, condenser, generator and evaporator temperatures on the system’s coefficient of performance was thoroughly analysed.

Zitieren

APA

Kaushik, S., Ram, S. C., Kishor, C., & Chamoli, S. (2026). Parametric Analysis of Heat Transfer and Flow Characteristics of the Cross-Flow Heat Exchanger with a Backwards Splitter Plate Using the Computational Fluid Dynamics (CFD) Model. Archives of Thermodynamics, 161-161. https://doi.org/10.24425/ather.2026.158667

Vancouver

Kaushik S, Ram SC, Kishor C, Chamoli S. Parametric Analysis of Heat Transfer and Flow Characteristics of the Cross-Flow Heat Exchanger with a Backwards Splitter Plate Using the Computational Fluid Dynamics (CFD) Model. Archives of Thermodynamics. 2026:161-161. doi:10.24425/ather.2026.158667

BibTeX
@article{Kaushik2026,
  author = {Kaushik, Sachin and Ram, Subash Chandra and Kishor, Chandra and Chamoli, Sunil},
  title = {Parametric Analysis of Heat Transfer and Flow Characteristics of the Cross-Flow Heat Exchanger with a Backwards Splitter Plate Using the Computational Fluid Dynamics (CFD) Model},
  journal = {Archives of Thermodynamics},
  year = {2026},
  pages = {161--161},
  doi = {10.24425/ather.2026.158667}
}
Kostenlos starten →