Controlled pre-magnetization method for inrush current reduction in electric arc furnace transformers
Archives of Electrical Engineering · 19.10.2026 · 75 (4)
DOI: 10.24425/aee.2026.6352 ↗Kurz gefasst
Fachartikel in der Zeitschrift Archives of Electrical Engineering, online erschienen am 19.10.2026. Verfasst von Sławomir Sowa und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
This paper investigates transformer inrush currents during the energisation of arc furnace transformers in electric arc furnace (EAF) power supply systems. The study focuses on an industrial DSP-100 installation operating with harmonic filters and reactive-power compensation equipment. A nonlinear reduced-order lumped-parameter model is formulated using explicit phase-domain relations for the supplying-system equivalent, the furnace-transformer branch, the connected filter/compensation branches, and the nonlinear magnetic circuit. The surviving DSP-100 oscillograms are used as an experimental anchor and for a waveform-level consistency assessment of peak current, inter-phase peak-current variation, and transient decay. Because the original high-resolution recorder export, complete channel documentation, and recorder characteristics are no longer available, this comparison is not presented as a unique experimental validation of the nonlinear saturation law or of the detailed nonsinusoidal inrush waveform. A model-level evaluation framework for controlled pre-magnetization is then formulated using peak inrush current, transient decay time, and an energy-based transient severity index. Relative peak-current error and RMSE are retained as waveform-consistency metrics, while the practical interpretation of the severity index is linked to equipment-specific I²t withstand limits. The experimentally anchored model provides a basis for comparative and sensitivity assessment of controlled pre-magnetization in the DSP-100 operating environment. Prototype-level confirmation of controller performance, nonlinear-waveform fidelity, and the influence on associated compensation and filtering equipment remains a subject of further industrial validation.
Zitieren
APA
Sowa, S., Hudym, V., Ziarkowski, S., Kosovska, V., & Kosovska, S. (2026). Controlled pre-magnetization method for inrush current reduction in electric arc furnace transformers. Archives of Electrical Engineering, 75(4). https://doi.org/10.24425/aee.2026.6352
Vancouver
Sowa S, Hudym V, Ziarkowski S, Kosovska V, Kosovska S. Controlled pre-magnetization method for inrush current reduction in electric arc furnace transformers. Archives of Electrical Engineering. 2026;75(4). doi:10.24425/aee.2026.6352
BibTeX
@article{Sowa2026,
author = {Sowa, Sławomir and Hudym, Vasyl and Ziarkowski, Sławomir and Kosovska, Vira and Kosovska, Solomia},
title = {Controlled pre-magnetization method for inrush current reduction in electric arc furnace transformers},
journal = {Archives of Electrical Engineering},
year = {2026},
volume = {75},
number = {4},
doi = {10.24425/aee.2026.6352}
}