EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Theoretical analysis of the secondary circuit of an electric arc furnace under three-phase unbalance condition

Weijian Li, Yang Yang, Longhu Cao

Archives of Electrical Engineering · 19.10.2026 · 75 (4)

DOI: 10.24425/aee.2026.6351 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Electrical Engineering, online erschienen am 19.10.2026. Verfasst von Weijian Li und 2 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

During electric arc furnace (EAF) smelting, three-phase load imbalance signifi-cantly affects electrical energy losses, temperature uniformity in the molten bath, and over-all smelting efficiency. Therefore, based on the three-phase unbalanced circuit of the EAF, this paper establishes a mathematical calculation model for key parameters related to pro-duction stability, including: neutral point voltage, three-phase voltage unbalance degree, three-phase currents, arc length, negative-sequence current, and voltage unbalance degree at the point of common coupling (PCC). Simulation results based on a 120 t EAF indicate that an increase in the impedance unbalance degree leads to a corresponding rise in neutral point voltage and three-phase voltage unbalance degree, accompanied by a marked increase in inter-phase current disparity and current unbalance degree. Notably, as the impedance unbalance degree escalates from 10% to 30%, the three-phase arc length difference widens from 26 mm to 79 mm, the relative negative-sequence current climbs from 2.89% to 8.76%, and the unbalance degree of PCC voltage increases from 0.276% to 0.846%. The theoretical findings presented in this paper provide a foundation for balanced compensation and oper-ational optimization of EAF power supply systems.

Zitieren

APA

Li, W., Yang, Y., & Cao, L. (2026). Theoretical analysis of the secondary circuit of an electric arc furnace under three-phase unbalance condition. Archives of Electrical Engineering, 75(4). https://doi.org/10.24425/aee.2026.6351

Vancouver

Li W, Yang Y, Cao L. Theoretical analysis of the secondary circuit of an electric arc furnace under three-phase unbalance condition. Archives of Electrical Engineering. 2026;75(4). doi:10.24425/aee.2026.6351

BibTeX
@article{Li2026,
  author = {Li, Weijian and Yang, Yang and Cao, Longhu},
  title = {Theoretical analysis of the secondary circuit of an electric arc furnace under three-phase unbalance condition},
  journal = {Archives of Electrical Engineering},
  year = {2026},
  volume = {75},
  number = {4},
  doi = {10.24425/aee.2026.6351}
}