Dual-method 3D FEM-based determination of d-q inductances in axial-flux permanent magnet synchronous generator taking saturation, magnet material and air-gap effects into account

Toan Luong Ngoc, Thanh Nguyen Vu, Doan Duc Tung, Vuong Dang Quoc

Archives of Electrical Engineering · 19.10.2026 · 75 (4)

DOI: 10.24425/aee.2026.3546 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives of Electrical Engineering, online erschienen am 19.10.2026. Verfasst von Toan Luong Ngoc und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents a method for determining the d and q axis inductances (Ld, Lq) of a 4 kW axial-flux permanent magnet synchronous generator (AFPMG) using combined 2D and 3D finite element method (FEM) simulation in Ansys Maxwell. The key contribution is a cross-validation framework employing two independent post-processing methods applied to the same FEM dataset: Method A, based on direct dq flux linkage extraction, and Method B, based on the phase inductance matrix (Labc) combined with coordinate transformation. The d-q mathematical model, including voltage equations, flux linkages, and saturation effects, is first summarized. The complete 3D FEM simulation procedure is described, from geome-try construction to inductance extraction, covering both static and transient analyses. Re-sults demonstrate that both methods yield consistent inductance values, within a maximum deviation of approximately 7-8%. At rated current, Ld ≈ 6.8 mH and Lq ≈ 6.4 mH are ob-tained from 3D static simulation (Method A), confirming the reliability of the proposed simulation approach. The influence of magnetic saturation, magnet material, and air-gap length on Ld and Lq is also systematically investigated. The determined Ld and Lq values serve as essential parameters for field-oriented control (FOC) design of the AFPMG, ena-bling accurate torque and flux regulation.

Zitieren

APA

Ngoc, T. L., Vu, T. N., Tung, D. D., & Quoc, V. D. (2026). Dual-method 3D FEM-based determination of d-q inductances in axial-flux permanent magnet synchronous generator taking saturation, magnet material and air-gap effects into account. Archives of Electrical Engineering, 75(4). https://doi.org/10.24425/aee.2026.3546

Vancouver

Ngoc TL, Vu TN, Tung DD, Quoc VD. Dual-method 3D FEM-based determination of d-q inductances in axial-flux permanent magnet synchronous generator taking saturation, magnet material and air-gap effects into account. Archives of Electrical Engineering. 2026;75(4). doi:10.24425/aee.2026.3546

BibTeX
@article{Ngoc2026,
  author = {Ngoc, Toan Luong and Vu, Thanh Nguyen and Tung, Doan Duc and Quoc, Vuong Dang},
  title = {Dual-method 3D FEM-based determination of d-q inductances in axial-flux permanent magnet synchronous generator taking saturation, magnet material and air-gap effects into account},
  journal = {Archives of Electrical Engineering},
  year = {2026},
  volume = {75},
  number = {4},
  doi = {10.24425/aee.2026.3546}
}
Kostenlos starten →