Microneedle fractional radiofrequency for reducing upper eyelid skin laxity: characteristics and comparison with other techniques
OphthaTherapy. Therapies in Ophthalmology · 12.06.2026 · 13 (1) · A0007
DOI: 10.24292/01.ot.250526 ↗Kurz gefasst
Fachartikel in der Zeitschrift OphthaTherapy. Therapies in Ophthalmology, online erschienen am 12.06.2026. Verfasst von Paulina Szabelska und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
The aim of the study was to present microneedle fractional radiofrequency as a method for reducing upper eyelid skin laxity and to compare it with other treatment techniques, both non-invasive and surgical. The article discusses the mechanism of action, technical parameters, clinical effects, and safety profile of microneedle radiofrequency. A comparative analysis with surgical blepharoplasty, fractional CO2 laser, HIFU, plasma, mesotherapy, and fillers was performed. The results showed that microneedle fractional radiofrequency is an effective and safe alternative for patients with mild to moderate upper eyelid skin laxity, offering visible improvement without a long recovery period. Although, surgical blepharoplasty remains the most effective method in advanced cases, non-invasive techniques are becoming increasingly important due to technological advances and growing patient expectations regarding comfort and procedural safety.
Zitieren
APA
Szabelska, P., Wereda-Wołkow, M., Cichowska, M., Jacuński, M., Mikołajewska, A., Strąk, A., & Różycki, R. (2026). Microneedle fractional radiofrequency for reducing upper eyelid skin laxity: characteristics and comparison with other techniques. OphthaTherapy. Therapies in Ophthalmology, 13(1), A0007. https://doi.org/10.24292/01.ot.250526
Vancouver
Szabelska P, Wereda-Wołkow M, Cichowska M, Jacuński M, Mikołajewska A, Strąk A, et al. Microneedle fractional radiofrequency for reducing upper eyelid skin laxity: characteristics and comparison with other techniques. OphthaTherapy. Therapies in Ophthalmology. 2026;13(1):A0007. doi:10.24292/01.ot.250526
BibTeX
@article{Szabelska2026,
author = {Szabelska, Paulina and Wereda-Wołkow, Magda and Cichowska, Magdalena and Jacuński, Mateusz and Mikołajewska, Anna and Strąk, Aleksander and Różycki, Radosław},
title = {Microneedle fractional radiofrequency for reducing upper eyelid skin laxity: characteristics and comparison with other techniques},
journal = {OphthaTherapy. Therapies in Ophthalmology},
year = {2026},
volume = {13},
number = {1},
pages = {A0007},
doi = {10.24292/01.ot.250526}
}