EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Normal H-reflex values in a Colombian population using electrodiagnostic characterization

Liseth Duarte-Amorocho, Carlos Eduardo Rangel-Galvis

Revista Investigación en Salud Universidad de Boyacá · 27.06.2025 · 12 (1. Enero-Junio)

DOI: 10.24267/23897325.1219 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Revista Investigación en Salud Universidad de Boyacá, online erschienen am 27.06.2025. Verfasst von Liseth Duarte-Amorocho und 1 weiteren Autor:innen. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

The Hoffmann reflex is a reflex elicited electrically by a weak percutaneous electrical stimulus belowthe motor threshold; its afferent depolarization generates an action potential that reaches the α-motoneurons andcreates an excitatory postsynaptic potential, observed as an H-reflex in the electrodiagnostic signal.

Objectives

To determine normal values of the L4 H-reflex in a healthy Colombian population using an electrodiagnostictechnique.Materials and Methods: Cross-sectional descriptive study with an analytical component. The sample included 25healthy Colombian individuals of both sexes, aged 20 to 60 years. Values within normal ranges were collected forlatency and amplitude of the L4 H-reflex in the vastus lateralis and rectus femoris muscles, bilaterally. The meanlatency of the L4 H-reflex in the vastus lateralis muscle was 13.29 ± 1.51 ms, with a mean amplitude of 1.55 ±0.46 mV. In the rectus femoris muscle, the mean latency was 13.14 ± 1.48 ms, and the mean amplitude was 1.52± 0.35 mV.

Conclusions

The findings show comparable excitability of the spinal reflex arcs associated with the vastus lateralisand rectus femoris muscles. Significant differences were identified in the morphology and architecture of the L4H-reflex between the two muscles, and a progressive increase in temperature was found to correlate with a significantreduction in the amplitude of the L4 H-reflex; however, no differences were observed in latency values, norin amplitude with respect to lower-limb laterality.

Zitieren

APA

Duarte-Amorocho, L., & Rangel-Galvis, C. E. (2025). Normal H-reflex values in a Colombian population using electrodiagnostic characterization. Revista Investigación en Salud Universidad de Boyacá, 12(1. Enero-Junio). https://doi.org/10.24267/23897325.1219

Vancouver

Duarte-Amorocho L, Rangel-Galvis CE. Normal H-reflex values in a Colombian population using electrodiagnostic characterization. Revista Investigación en Salud Universidad de Boyacá. 2025;12(1. Enero-Junio). doi:10.24267/23897325.1219

BibTeX
@article{DuarteAmorocho2025,
  author = {Duarte-Amorocho, Liseth and Rangel-Galvis, Carlos Eduardo},
  title = {Normal H-reflex values in a Colombian population using electrodiagnostic characterization},
  journal = {Revista Investigación en Salud Universidad de Boyacá},
  year = {2025},
  volume = {12},
  number = {1. Enero-Junio},
  doi = {10.24267/23897325.1219}
}
Kostenlos starten →