Calculation of Gallium-68 Dose Factors for [68Ga] DOTATATE Injected Patients: A Comparison with OLINDA Database
Journal of Nuclear Research and Applications · 2022
DOI: 10.24200/jon.2022.1018 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Nuclear Research and Applications, 2022. Verfasst von S. Karimkhani und 4 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref).
Abstract (Originalsprache)
[68Ga] DOTATATE as a radiolabeled tracer is used for in vivo detection of neuroendocrine tumors in the PET/CT examinations. This study aims to calculate S-values in various organs in a voxelized-based Monte Carlo simulation approach for each patient individually. PET/CT images of 9 patients suspected of neuroendocrine cancer were acquired 60 minutes after injection of [68Ga] DOTATATE. After reshaping and registering CT images to the size of PET images, GATE/GEANT4 Monte Carlo (MC) toolkit was used with two inputs of CT images as voxelized attenuation map and PET images as a voxelized activity map for the calculation of the different organs dose. Voxelized dose maps were extracted in the target organs for different source organs. S-value volume histogram and absolute S-values based on the MIRD formalism were calculated. The highest S-values were observed for spleen, bladder, kidneys, liver, pituitary, and the lung with 6.26E-05 ± 1.47E-05, 5.17E-05 ± 3.08E-05, 3.41E-05 ± 7.68E-06, 2.08E-05 ± 4.12E-06, 1.62E-05 ± 5.74E-06 and 8.47E-06 ± 2.47E-06 mGy/MBq.S, respectively. The difference between the amounts of the calculated S-values and those presented in OLINDA software is mainly related to the anatomical difference of the patients with the standard phantom in OLINEDA software. This study showed that patient-specific dosimetry is necessary to calculate S-values.
Zitieren
APA
Karimkhani, S., Yousefnia, H., Faghihi, R., Gramifar, P., & Parishan, M. R. (2022). Calculation of Gallium-68 Dose Factors for [68Ga] DOTATATE Injected Patients: A Comparison with OLINDA Database. Journal of Nuclear Research and Applications. https://doi.org/10.24200/jon.2022.1018
Vancouver
Karimkhani S, Yousefnia H, Faghihi R, Gramifar P, Parishan MR. Calculation of Gallium-68 Dose Factors for [68Ga] DOTATATE Injected Patients: A Comparison with OLINDA Database. Journal of Nuclear Research and Applications. 2022. doi:10.24200/jon.2022.1018
BibTeX
@article{Karimkhani2022,
author = {Karimkhani, S. and Yousefnia, H. and Faghihi, R. and Gramifar, P. and Parishan, M. R.},
title = {Calculation of Gallium-68 Dose Factors for [68Ga] DOTATATE Injected Patients: A Comparison with OLINDA Database},
journal = {Journal of Nuclear Research and Applications},
year = {2022},
doi = {10.24200/jon.2022.1018}
}