EUVIMEDEUVIMED entdecken
Crossref

Use of the Traditional Wattmetric Function in Networks with Zig-Zag Transformer Grounding

I. San Sebastian, Felipe Uriondo, Endika Garcia, Juan María Garcia

Energies and Quality Journal · 2026-07 · 4 (2) · 158-163

DOI: 10.24084/eqj26-338 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Energies and Quality Journal, 2026-07. Verfasst von I. San Sebastian und 3 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The earliest electrical protection systems consisted of simple overcurrent relays (functions 50/51) that measured only the magnitude of the current. Later, European engineers—particularly in Germany and the Nordic countries, where compensated-neutral networks were common—began to adapt the directional principle to zero-sequence currents (function 67N). The purpose was to determine whether the ground fault was located within the protected section, thus avoiding unnecessary tripping in other parts of the system [1–4]. In systems with isolated or Petersen-coil grounded neutrals, the 67N function provides excellent selectivity but when a system is grounded through a zig-zag transformer, selectivity becomes even more challenging if the protected line has significant capacitive contribution [5]. This paper presents the existing difficulties in achieving selectivity in networks grounded through zig-zag transformers combined with lines that carry high capacitive current. Once the problem is described, a simple and cost-effective solution is proposed based on the wattmetric protection function to obtain an appropriate selectivity. The solution presented in this paper is already implemented in the field. Key words. Zig-Zag transformer, Wattmetric protection, Forward fault, Reverse fault, Zero-sequence.

Zitieren

APA

Sebastian, I. S., Uriondo, F., Garcia, E., & Garcia, J. M. (2026). Use of the Traditional Wattmetric Function in Networks with Zig-Zag Transformer Grounding. Energies and Quality Journal, 4(2), 158-163. https://doi.org/10.24084/eqj26-338

Vancouver

Sebastian IS, Uriondo F, Garcia E, Garcia JM. Use of the Traditional Wattmetric Function in Networks with Zig-Zag Transformer Grounding. Energies and Quality Journal. 2026;4(2):158-163. doi:10.24084/eqj26-338

BibTeX
@article{Sebastian2026,
  author = {Sebastian, I. San and Uriondo, Felipe and Garcia, Endika and Garcia, Juan María},
  title = {Use of the Traditional Wattmetric Function in Networks with Zig-Zag Transformer Grounding},
  journal = {Energies and Quality Journal},
  year = {2026},
  volume = {4},
  number = {2},
  pages = {158--163},
  doi = {10.24084/eqj26-338}
}
Kostenlos starten →