EUVIMEDEUVIMED entdecken
Crossref

Evaluation of resorbable ZN-MG alloy biocompatibility in vitro and in vivo

II Gordienko, DO Kornilov, SP Chernyi, VM Simarzina, DY Rasposienko, AE Slukina, MI Ivasenko, DE Vinokurov, DL Zornikov

Bulletin of Russian State Medical University · 04.06.2026 · (3)

DOI: 10.24075/brsmu.2026.026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bulletin of Russian State Medical University, online erschienen am 04.06.2026. Verfasst von II Gordienko und 8 weiteren Autor:innen. Die Arbeit nennt 29 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Bioabsorbable Zn–Mg alloys are considered an alternative to metallic fixators, but data on their biocompatibility at low Mg content remain insufficient. Aim — to evaluate the biocompatibility of Zn–Mg alloys containing 0.5–2 wt.% Mg in vitro and in vivo. Cytotoxicity of Zn–0.5Mg and Zn–1Mg powders (0.15–2.5 mg/mL) was assessed in direct contact with SCP‑1 cells (MTT assay). In vivo, cylindrical implants of four compositions were placed bilaterally into the tibial metaphysis of rabbits (n = 4). Complete blood count was performed on day 7; computed tomography (CT) was performed at 3 and 10 months. At 2.5 mg/mL, cell viability was 12.5 ± 1.0 % (Zn–0.5Mg) and 16.8 ± 1.6% (Zn–1Mg). At 1.25 mg/mL, Zn–1Mg showed no toxicity (101.4 ± 3.3 %), whereas Zn–0.5Mg remained cytotoxic (51.3 ± 4.4 %). Recovery to > 80 % viability was observed at 0.62 mg/mL for Zn–0.5Mg and 0.31 mg/mL for Zn–1Mg. In vivo, all animals maintained normal activity; haematological parameters were within normal range. At 3 months, CT showed stable implants without signs of osteolysis. Cortical bone density was 647.3 ± 5.4 HU, trabecular bone density was 510.5 ± 6.4 HU, comparable to intact bone. At 10 months, implants remained visible. Zn–Mg alloys with 0.5–2 wt.% Mg exhibit dose‑dependent cytotoxicity in vitro and satisfactory biocompatibility in vivo without systemic inflammatory reactions or bone resorption over 10 months. The alloy with 1% Mg has a more favourable cell viability profile.

Zitieren

APA

Gordienko, I., Kornilov, D., Chernyi, S., Simarzina, V., Rasposienko, D., Slukina, A., Ivasenko, M., Vinokurov, D., & Zornikov, D. (2026). Evaluation of resorbable ZN-MG alloy biocompatibility in vitro and in vivo. Bulletin of Russian State Medical University. https://doi.org/10.24075/brsmu.2026.026

Vancouver

Gordienko I, Kornilov D, Chernyi S, Simarzina V, Rasposienko D, Slukina A, et al. Evaluation of resorbable ZN-MG alloy biocompatibility in vitro and in vivo. Bulletin of Russian State Medical University. 2026. doi:10.24075/brsmu.2026.026

BibTeX
@article{Gordienko2026,
  author = {Gordienko, II and Kornilov, DO and Chernyi, SP and Simarzina, VM and Rasposienko, DY and Slukina, AE and Ivasenko, MI and Vinokurov, DE and Zornikov, DL},
  title = {Evaluation of resorbable ZN-MG alloy biocompatibility in vitro and in vivo},
  journal = {Bulletin of Russian State Medical University},
  year = {2026},
  number = {3},
  doi = {10.24075/brsmu.2026.026}
}
Kostenlos starten →