Evaluation of absorbed dose distribution in melanoma B16F10 during contrast enhanced radiotherapy with intratumoral administration of dose-enhancing agent
Bulletin of Russian State Medical University · 17.12.2018 · ((5)2018) · 60-64
DOI: 10.24075/brsmu.2018.062 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bulletin of Russian State Medical University, online erschienen am 30.11.2018. Verfasst von AA Lipengolts und 9 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 26 Literaturangaben. Gefördert von: Russian Science Foundation.
Abstract (Originalsprache)
Contrast-enhanced radiotherapy (CERT) is a binary treatment modality in which the absorbed radiation dose is not only determined by the parameters of the external radiation source but also affected by the concentration of a dose-enhancing agent (DEA) in the studied object. In this work we assessed the distribution of the absorbed dose in a murine B16F10 melanoma injected with a single dose of an aqueous Bi-DTPA solution. The mice were exposed to a single fraction of X-ray irradiation for 28.5 min. In vivo measurements of DEA concentrations were done on a micro-CT scanner using the radiopacity values of malignant tissues from the obtained CT images. We found that the presence of DEA enhanced the absorbed dose more than twofold in 6% of the tumor volume; in 29% of the tumor volume the absorbed dose increased more than onefold. The tumor growth delay time calculated for our model was 0.76 days (we only accounted for the damage caused directly by radiation), whereas in our previous research study tumor growth delay was 10 days. This discrepancy may indicate that in the tumors exposed to contrast-enhanced radiotherapy growth delay results from both the damage directly caused by radiation and other antitumor mechanisms.
Förderung
- Russian Science Foundation
Zitieren
APA
Lipengolts, A., Vorobyeva, E., Cherepanov, A., Abakumov, M., Abakumova, T., Smirnova, A., Finogenova, Y., Grigorieva, E., Sheino, I., & Kulakov, V. (2018). Evaluation of absorbed dose distribution in melanoma B16F10 during contrast enhanced radiotherapy with intratumoral administration of dose-enhancing agent. Bulletin of Russian State Medical University, 60-64. https://doi.org/10.24075/brsmu.2018.062
Vancouver
Lipengolts A, Vorobyeva E, Cherepanov A, Abakumov M, Abakumova T, Smirnova A, et al. Evaluation of absorbed dose distribution in melanoma B16F10 during contrast enhanced radiotherapy with intratumoral administration of dose-enhancing agent. Bulletin of Russian State Medical University. 2018:60-64. doi:10.24075/brsmu.2018.062
BibTeX
@article{Lipengolts2018,
author = {Lipengolts, AA and Vorobyeva, ES and Cherepanov, AA and Abakumov, MA and Abakumova, TO and Smirnova, AV and Finogenova, YuA and Grigorieva, EYu and Sheino, IN and Kulakov, VN},
title = {Evaluation of absorbed dose distribution in melanoma B16F10 during contrast enhanced radiotherapy with intratumoral administration of dose-enhancing agent},
journal = {Bulletin of Russian State Medical University},
year = {2018},
number = {(5)2018},
pages = {60--64},
doi = {10.24075/brsmu.2018.062}
}
EUVIMED