Comparative Assessment of Deterministic and Probabilistic Load Flow Under Solar Irradiance Variability in PV-Integrated Distribution Networks
INVOTEK: Jurnal Inovasi Vokasional dan Teknologi · 16.01.2026 · 25 (2) · 165-176
DOI: 10.24036/invotek.v25i2.1302 ↗Kurz gefasst
Fachartikel in der Zeitschrift INVOTEK: Jurnal Inovasi Vokasional dan Teknologi, online erschienen am 16.01.2026. Verfasst von Erita Astrid und 4 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
The increasing penetration of photovoltaic (PV) generation in modern distribution networks introduces considerable uncertainty due to the inherently fluctuating nature of solar irradiance. These fluctuations directly affect PV output power, resulting in significant variations in bus voltages, feeder currents, and power losses. Traditional deterministic load flow (DLF) analysis, which assumes fixed PV generation, is unable to capture this stochastic behavior and therefore may lead to inaccurate estimation of system conditions. This study presents a comparative assessment between deterministic load flow using the Backward–Forward Sweep (BFS) method and probabilistic load flow (PLF) based on Hong’s Two-Point Estimate Method (PEM) to evaluate the impact of solar irradiance variability on the performance of PV-integrated distribution networks. Solar irradiance data are statistically characterized to obtain the mean and variance, which are then propagated into PV output power through a linear irradiance–power conversion model. The IEEE 34-bus radial distribution system is used as the test network, with multiple PV units installed at selected buses. The results show that deterministic analysis underestimates voltage deviations and fails to capture the range of power losses induced by PV uncertainty. In particular, the deterministic BFS solution yields a single operating point with real and reactive losses of 0.1582 MW and 0.0479 MVar, whereas the probabilistic 2PEM produces mean losses of 0.105 MW and 0.031 MVar with standard deviations of 0.057 MW and 0.016 MVar, respectively. In contrast to the fixed deterministic voltage curve, probabilistic voltage profiles form a bounded envelope around it, indicating non-negligible downstream voltage variability driven by irradiance fluctuations. Overall, the findings confirm that solar irradiance variability substantially influences distribution system performance, and incorporating probabilistic assessment is essential for more realistic, risk-informed planning and operation of PV-integrated distribution systems.
Zitieren
APA
Astrid, E., Simamora, Y., Solihin, M. D., Suryanto, E. D., & Salman, R. (2026). Comparative Assessment of Deterministic and Probabilistic Load Flow Under Solar Irradiance Variability in PV-Integrated Distribution Networks. INVOTEK: Jurnal Inovasi Vokasional dan Teknologi, 25(2), 165-176. https://doi.org/10.24036/invotek.v25i2.1302
Vancouver
Astrid E, Simamora Y, Solihin MD, Suryanto ED, Salman R. Comparative Assessment of Deterministic and Probabilistic Load Flow Under Solar Irradiance Variability in PV-Integrated Distribution Networks. INVOTEK: Jurnal Inovasi Vokasional dan Teknologi. 2026;25(2):165-176. doi:10.24036/invotek.v25i2.1302
BibTeX
@article{Astrid2026,
author = {Astrid, Erita and Simamora, Yoakim and Solihin, Muhammad Dani and Suryanto, Eka Dodi and Salman, Rudi},
title = {Comparative Assessment of Deterministic and Probabilistic Load Flow Under Solar Irradiance Variability in PV-Integrated Distribution Networks},
journal = {INVOTEK: Jurnal Inovasi Vokasional dan Teknologi},
year = {2026},
volume = {25},
number = {2},
pages = {165--176},
doi = {10.24036/invotek.v25i2.1302}
}
EUVIMED