Analysis of the Effects of Proton Energy and Silicon Detector Thickness on the Total Ionizing Dose (TID) Using Phits Monte Carlo Simulation
PILLAR OF PHYSICS · 30.04.2026 · 19 (1) · 1-8
DOI: 10.24036/axdg7y88 ↗Kurz gefasst
Fachartikel in der Zeitschrift PILLAR OF PHYSICS, online erschienen am 30.04.2026. Verfasst von Sitti Yani und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).
Abstract (Originalsprache)
This study analyzes the effects of proton energy and silicon detector thickness on particle distribution and dosimetric response using Monte Carlo simulations based on the Particle and Heavy Ion Transport System (PHITS) code. Simulations were performed at two proton energies, namely 25 MeV and 100 MeV, with variations in silicon detector thickness grouped into thin and bulk categories. The analyzed results include the two-dimensional distributions of protons, secondary photons, and secondary neutrons, as well as the Total Ionizing Dose (TID) values in the silicon detector. The simulation results show that the proton distribution is clearly influenced by particle energy, where 100 MeV protons have a longer transport range and more dominant penetration compared to 25 MeV protons. Conversely, visual differences in the distribution of secondary particles, namely photons and neutrons, across all energy and thickness variations are not clearly apparent in the obtained two-dimensional maps. From a dosimetric perspective, TID increases linearly with increasing silicon detector thickness for both proton energies. Furthermore, the TID values at 100 MeV are consistently higher than those at 25 MeV across all thickness variations. Analysis of the D100(t)/D25(t) ratio indicates that an increase in proton energy enhances the dosimetric response at every detector thickness. These results confirm that within the detector thickness range of 0.001 cm to 0.5 cm, thickness directly determines the magnitude of TID, while proton energy enhances the detector’s dosimetric response.
Zitieren
APA
Yani, S., Fartini, S. K. S., Adiati, R. F., & Sumaryada, T. (2026). Analysis of the Effects of Proton Energy and Silicon Detector Thickness on the Total Ionizing Dose (TID) Using Phits Monte Carlo Simulation. PILLAR OF PHYSICS, 19(1), 1-8. https://doi.org/10.24036/axdg7y88
Vancouver
Yani S, Fartini SKS, Adiati RF, Sumaryada T. Analysis of the Effects of Proton Energy and Silicon Detector Thickness on the Total Ionizing Dose (TID) Using Phits Monte Carlo Simulation. PILLAR OF PHYSICS. 2026;19(1):1-8. doi:10.24036/axdg7y88
BibTeX
@article{Yani2026,
author = {Yani, Sitti and Fartini, Siti Karmilah Syahri and Adiati, Rima Fitria and Sumaryada, Tony},
title = {Analysis of the Effects of Proton Energy and Silicon Detector Thickness on the Total Ionizing Dose (TID) Using Phits Monte Carlo Simulation},
journal = {PILLAR OF PHYSICS},
year = {2026},
volume = {19},
number = {1},
pages = {1--8},
doi = {10.24036/axdg7y88}
}
EUVIMED