EUVIMEDEUVIMED entdecken
Open Access · CC BY-SA 4.0

IDENTIFICATION OF LIQUEFACTION POTENTIAL IN KOTO TANGAH SUBDISTRICT OF PADANG CITY USING SCHLUMBERGER CONFIGURATION GEOELECTRIC METHOD

Nelma Yeti, Akmam Akmam, Hamdi Hamdi, Nofi Yendri Sudiar

PILLAR OF PHYSICS · 30.04.2026 · 19 (1) · 18-26

DOI: 10.24036/89zdna28 ↗

Kurz gefasst

Fachartikel in der Zeitschrift PILLAR OF PHYSICS, online erschienen am 30.04.2026. Verfasst von Nelma Yeti und 3 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-SA 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The earthquake of September 30 2009, showed that Lubuk Buaya Sub-district, Koto Tangah Sub-district, Padang City is an earthquake-prone area, and the geology of the area consisting of sandstone and alluvium deposits is a contributing factor to liquefaction. Research on liquefaction potential using the Schlumberger configuration geoelectric method has never been conducted in this area, although initial observations showed indications of liquefaction in buildings and infrastructure. Therefore, this study aims to determine the description of soil layers that have the potential to experience liquefaction based on the value of rock specific resistance in Lubuk Buaya Village. This research used a descriptive field approach, conducted from February to June 2025 with four measurement tracks, each 155 meters long and 5 meters electrode spacing. Using the Automatic Resistivity System (ARES) instrument. The data obtained include electric current strength (I), potential difference (V), and electrode spacing which are processed to determine the value of geometry factor and apparent density resistance (ρa). Data interpretation was carried out using the Smoothness Constraint Least Squares inversion method with the help of Res2dinv software to produce true specific gravity and depth. The results showed that the subsurface soil layers in Lubuk Buaya Village have a high potential to experience liquefaction. This potentially liquefiable soil layer consists of water-saturated sand, gravel, and sandy silt, with low resistivity values. Liquefaction potential zones were identified at depths of 5 to 25 meters with a thickness of 20 meters.

Zitieren

APA

Yeti, N., Akmam, A., Hamdi, H., & Sudiar, N. Y. (2026). IDENTIFICATION OF LIQUEFACTION POTENTIAL IN KOTO TANGAH SUBDISTRICT OF PADANG CITY USING SCHLUMBERGER CONFIGURATION GEOELECTRIC METHOD. PILLAR OF PHYSICS, 19(1), 18-26. https://doi.org/10.24036/89zdna28

Vancouver

Yeti N, Akmam A, Hamdi H, Sudiar NY. IDENTIFICATION OF LIQUEFACTION POTENTIAL IN KOTO TANGAH SUBDISTRICT OF PADANG CITY USING SCHLUMBERGER CONFIGURATION GEOELECTRIC METHOD. PILLAR OF PHYSICS. 2026;19(1):18-26. doi:10.24036/89zdna28

BibTeX
@article{Yeti2026,
  author = {Yeti, Nelma and Akmam, Akmam and Hamdi, Hamdi and Sudiar, Nofi Yendri},
  title = {IDENTIFICATION OF LIQUEFACTION POTENTIAL IN KOTO TANGAH SUBDISTRICT OF PADANG CITY USING SCHLUMBERGER CONFIGURATION GEOELECTRIC METHOD},
  journal = {PILLAR OF PHYSICS},
  year = {2026},
  volume = {19},
  number = {1},
  pages = {18--26},
  doi = {10.24036/89zdna28}
}
Kostenlos starten →