REDUCING THE REQUIRED DRIVE TORQUE OF A DOUBLE-UNBALANCED VIBRATORY FEEDER USING FREQUENCY CONTROL
Ukrainian Journal of Mechanical Engineering and Materials Science · 2026 · 12 (3) · 67-76
DOI: 10.23939/ujmems2026.03.067 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ukrainian Journal of Mechanical Engineering and Materials Science, 2026. Verfasst von Maksym Yukhymenko und 1 weiteren Autor:innen. Die Arbeit nennt 11 Literaturangaben.
Abstract (Originalsprache)
Problem Statement. Vibratory feeders are widely used in industrial technological processes for transportation, dosing, and feeding of bulk materials. Conventional approaches to designing vibratory feeders often rely on oversized electric drives, which leads to excessive energy consumption and reduced operational efficiency. The application of frequency-controlled drives creates new opportunities for optimizing the operating modes of vibratory systems while reducing installed motor power without compromising technological performance.
Purpose
The purpose of this study is to determine the reduction in the required drive torque of a double-unbalanced vibratory feeder achieved by frequency-controlled startup. Methodology. A mathematical model of a vibratory feeder equipped with independently driven unbalanced vibration exciters was developed. Dynamic equations describing the system's oscillatory motion were derived and implemented in MATLAB/Simulink. Numerical simulations were performed to investigate transient and steady-state operating modes for different drive power values and excitation frequencies. The obtained angular velocities, phase relations, trough-motion parameters, and startup conditions were analyzed and compared for direct and frequency-controlled startups.
Findings
The simulation results demonstrate that frequency control enables stable synchronization of independently driven vibration exciters and ensures the required oscillation parameters even when the installed drive power is significantly reduced. The obtained transient characteristics confirm reliable system operation during start-up and steady-state conditions while maintaining stable vibration amplitudes required for efficient material transportation. The simulation results demonstrate that frequency-controlled startup substantially reduces the required peak motor torque while maintaining stable synchronization of the unbalanced exciters. Originality. The scientific contribution consists of determining, by numerical simulation, the limiting motor torque required for successful transition through the resonance zone under direct and frequency-controlled startup conditions. Practical Value. The proposed methodology can be applied during the design and modernization of industrial vibratory feeders equipped with frequency-controlled drives, allowing manufacturers to reduce energy consumption, improve operational efficiency, and decrease operating costs. Scopes of Further Investigations. Future studies will focus on experimental validation of the proposed mathematical model, optimization of frequency control algorithms, and investigation of feeder performance under varying loading conditions and bulk material types.
Zitieren
APA
Yukhymenko, M., & Topilnytskyy, V. (2026). REDUCING THE REQUIRED DRIVE TORQUE OF A DOUBLE-UNBALANCED VIBRATORY FEEDER USING FREQUENCY CONTROL. Ukrainian Journal of Mechanical Engineering and Materials Science, 12(3), 67-76. https://doi.org/10.23939/ujmems2026.03.067
Vancouver
Yukhymenko M, Topilnytskyy V. REDUCING THE REQUIRED DRIVE TORQUE OF A DOUBLE-UNBALANCED VIBRATORY FEEDER USING FREQUENCY CONTROL. Ukrainian Journal of Mechanical Engineering and Materials Science. 2026;12(3):67-76. doi:10.23939/ujmems2026.03.067
BibTeX
@article{Yukhymenko2026,
author = {Yukhymenko, Maksym and Topilnytskyy, Volodymyr},
title = {REDUCING THE REQUIRED DRIVE TORQUE OF A DOUBLE-UNBALANCED VIBRATORY FEEDER USING FREQUENCY CONTROL},
journal = {Ukrainian Journal of Mechanical Engineering and Materials Science},
year = {2026},
volume = {12},
number = {3},
pages = {67--76},
doi = {10.23939/ujmems2026.03.067}
}
EUVIMED