EXERGY ANALYSIS AND THERMODYNAMIC–KINETIC OPTIMIZATION OF ENERGY EFFICIENCY IN AN INDUSTRIAL 60-T LADLE VACUUM DEGASSING UNIT
Ukrainian Journal of Mechanical Engineering and Materials Science · 2026 · 12 (3) · 37-46
DOI: 10.23939/ujmems2026.03.037 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ukrainian Journal of Mechanical Engineering and Materials Science, 2026. Verfasst von Imamverdi A. Behbudlu. Die Arbeit nennt 13 Literaturangaben.
Abstract (Originalsprache)
Ladle vacuum degassing is an energy-intensive stage of secondary steelmaking in which the efficiency of gas removal is strongly influenced by vacuum pressure, pressure stability, melt temperature, and inert-gas stirring conditions. This study develops and validates an integrated thermodynamic–kinetic and exergy-based framework to improve the energy efficiency of an industrial 60-t ladle vacuum degassing unit at Baku Steel Company. The proposed approach combines a Sieverts-law-based first-order kinetic description of hydrogen and nitrogen removal with an empirical pressure–temperature model, a heat balance of the ladle system, and second-law exergy analysis. Model parameters were identified using industrial measurements obtained during an annual campaign of approximately 950 heats, including gas analysis, temperature monitoring, vacuum and pressure recording, and electric energy metering. The results demonstrate that the most favorable operating conditions are achieved under a stable vacuum below 5 mbar, with a pressure-fluctuation rate not exceeding 0.5 mbar/s, an argon flow rate of 12–14 m³/h, and a steel temperature of 1550–1650 °C. Vacuum instability was found to reduce the apparent nitrogen mass-transfer coefficient from 0.021 to 0.008 min⁻¹, corresponding to a decrease of approximately 60%. Deepening the vacuum from 10 to 1 mbar increased hydrogen removal from 82 to 94% and nitrogen removal from 73 to 84%, while reducing the electric energy consumption from 3.8 to 3.3 MWh per heat. The combined optimization measures provide an overall energy saving of 12–18%, equivalent to approximately 15–18 kWh/t. Exergy analysis showed that the baseline efficiency of approximately 72% can be increased to about 82% by reducing heat-transfer losses, improving vacuum stability, and optimizing argon dispersion. The analysis also revealed a distinction between the first-law optimum, associated with deep vacuum near 1 mbar, and the exergy-optimal steady operating range of 5–6 mbar. The developed framework provides a quantitative basis for energy-efficient control of industrial vacuum degassing and may support the further implementation of adaptive control and digital-twin technologies.
Zitieren
APA
Behbudlu, I. A. (2026). EXERGY ANALYSIS AND THERMODYNAMIC–KINETIC OPTIMIZATION OF ENERGY EFFICIENCY IN AN INDUSTRIAL 60-T LADLE VACUUM DEGASSING UNIT. Ukrainian Journal of Mechanical Engineering and Materials Science, 12(3), 37-46. https://doi.org/10.23939/ujmems2026.03.037
Vancouver
Behbudlu IA. EXERGY ANALYSIS AND THERMODYNAMIC–KINETIC OPTIMIZATION OF ENERGY EFFICIENCY IN AN INDUSTRIAL 60-T LADLE VACUUM DEGASSING UNIT. Ukrainian Journal of Mechanical Engineering and Materials Science. 2026;12(3):37-46. doi:10.23939/ujmems2026.03.037
BibTeX
@article{Behbudlu2026,
author = {Behbudlu, Imamverdi A.},
title = {EXERGY ANALYSIS AND THERMODYNAMIC–KINETIC OPTIMIZATION OF ENERGY EFFICIENCY IN AN INDUSTRIAL 60-T LADLE VACUUM DEGASSING UNIT},
journal = {Ukrainian Journal of Mechanical Engineering and Materials Science},
year = {2026},
volume = {12},
number = {3},
pages = {37--46},
doi = {10.23939/ujmems2026.03.037}
}
EUVIMED