Background

Out-of-hours (OOH) CT and MRI examinations at our institution are provisionally reported by on-call radiology residents and used to guide overnight patient management. We aimed to (1) quantify the overnight discrepancy rate between provisional resident reports and subsequent consultant reports, and (2) explore associations between discrepancies and resident grade, study type, and reporting time.

Methods

This registered service evaluation retrospectively reviewed all consecutive CT and MRI examinations provisionally reported overnight by radiology residents between 13 June 2022 and 3 July 2022. Provisional reports were compared with the final consultant reports. Discrepancies were categorised as minor, significant, or major using predefined criteria by an ST4 radiology resident.

Results

In total, 993 imaging examinations were included. The overall discrepancy rate (DR) was 14.5% (144/993). Major and significant discrepancies comprised 56/993 scans (5.6%) and were considered potentially management‑altering. Variation in DR by one‑hour time block was not statistically significant (χ2 test, p = 0.37).

Conclusion

The overall discrepancy rate for overnight resident provisional reporting was 14.5%, with 5.6% of examinations containing potentially management-altering discrepancies. Discrepancies appeared to cluster during busier periods, suggesting that workload and interruptions may contribute more than fatigue alone. Targeted interventions focused on high-activity periods may help reduce clinically significant discrepancies. Clinical relevance statement: Quantifying and characterising overnight reporting discrepancies can identify modifiable factors-such as workload and interruptions-that may improve reporting accuracy and patient safety in OOH settings.

Zitieren

APA

Dean, M., Qadi, H., Rana, A., Yip, K. Y., & Burton, A. G. (2026). Accuracy of Provisional Reports by Radiology Residents on Call. International Journal of Radiology and Imaging Technology, 12(1), 1-7. https://doi.org/10.23937/2572-3235.1510142

Vancouver

Dean M, Qadi H, Rana A, Yip KY, Burton AG. Accuracy of Provisional Reports by Radiology Residents on Call. International Journal of Radiology and Imaging Technology. 2026;12(1):1-7. doi:10.23937/2572-3235.1510142

BibTeX
@article{Dean2026,
  author = {Dean, Mariam and Qadi, Hammad and Rana, Ali and Yip, Kar Yan and Burton, Anmol Gangi},
  title = {Accuracy of Provisional Reports by Radiology Residents on Call},
  journal = {International Journal of Radiology and Imaging Technology},
  year = {2026},
  volume = {12},
  number = {1},
  pages = {1--7},
  doi = {10.23937/2572-3235.1510142}
}
Kostenlos starten →