Introduction
Percutaneous nephrostomy (PCN) catheter exchange is commonly performed using standard over-the-wire techniques; however, exchange may be challenging or unsuccessful in the setting of catheter encrustation. Failure of nephrostomy exchange may necessitate de novo renal access, increasing procedural risk and resource utilization. We describe a modified sheath technique to facilitate catheter exchange in difficult cases.
Methods
All cases of nephrostomy tube exchange performed using a modified sheath technique between February 2025 and January 2026 at a single tertiary center were retrospectively reviewed. Patients with encrusted nephrostomy tubes in whom conventional wire-guided exchange failed were included. Procedural technique, demographic data, technical success, and complications were evaluated.
Results
Technical success was achieved in 19 of 20 cases (95%) of encrusted nephrostomy tubes using the modified sheath technique. In one case, loss of tract access occurred due to sheath buckling, and the procedure was abandoned. No major procedure-related complications were observed.
Conclusion
Nephrostomy tube exchange using a modified sheath technique demonstrates a high technical success rate in cases of challenging encrusted nephrostomy tubes. This fluoroscopy-guided approach preserves collecting system access and may serve as a practical minimally invasive salvage option in routine interventional radiology practice.
Zitieren
APA
Shiu, W. H. L., & Chan, K. W. (2026). Non-invasive Exchange of Encrusted Nephrostomy Tubes Using a Modified Sheath Technique: Technical Description and Case Series. International Journal of Radiology and Imaging Technology, 12(1), 1-4. https://doi.org/10.23937/2572-3235.1510141
Vancouver
Shiu WHL, Chan KW. Non-invasive Exchange of Encrusted Nephrostomy Tubes Using a Modified Sheath Technique: Technical Description and Case Series. International Journal of Radiology and Imaging Technology. 2026;12(1):1-4. doi:10.23937/2572-3235.1510141
BibTeX
@article{Shiu2026,
author = {Shiu, Wai Hung Lester and Chan, Kin Wong},
title = {Non-invasive Exchange of Encrusted Nephrostomy Tubes Using a Modified Sheath Technique: Technical Description and Case Series},
journal = {International Journal of Radiology and Imaging Technology},
year = {2026},
volume = {12},
number = {1},
pages = {1--4},
doi = {10.23937/2572-3235.1510141}
}
EUVIMED