EUVIMEDEUVIMED entdecken
Crossref

High Performance Liquid Chromatography Validation of Isoniazid Analysis Method in 2 Fixed-Dose Combination Dispersible Tablet

Lia Puspitasari, Chyntia Yoane Putri, Saiful Bahri, Putri Kharisma Novita Sari, Fitrawan Hernuza Pribadi, Akbar Eka Nugraha

Pharmacon: Jurnal Farmasi Indonesia · 30.06.2026 · 60-68

DOI: 10.23917/pharmacon.v23i1.6912 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Pharmacon: Jurnal Farmasi Indonesia, online erschienen am 30.06.2026. Verfasst von Lia Puspitasari und 5 weiteren Autor:innen. Die Arbeit nennt 21 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Tuberculosis (TB) is a severe disease that causes significant morbidity and mortality worldwide, including in children. Combination therapy of isoniazid and rifampicin (two-fixed drug combination (2 FDC)) is recommended for children in the advanced stage, based on body weight. The dissolving test requirements for producing two FDC dispersible tablets, however, are not listed in the Indonesian Pharmacopoeia or other standard book. Because the only method of analysis presently in use is the ratio of the outcomes of the rifampicin and isoniazid dissolutions in the capsules, new methods of analysis must be developed and validated for dispersible tablets. This research aims to develop analytical methods for determining isoniazid levels in 2 FDC dispersible tablet formulations. The method uses High Performance Liquid Chromatography (HPLC) with a C18 column (4.6 mm x 250 mm, 5 µm) and UV-Vis detectors at 254 nm. The mobile phase is Water:Phosphate Buffer:Methanol (850:50:10), which is delivered at a flow rate of 1.5 ml/min. The validation parameter test results in correlation coefficients (r) 0.9995, LOD 0,00038724 mg/mL, LOQ 0.00117346 mg/mL, % recovery 99.51% in the accuracy test, and %RSD 0.41% in the precision tests. The results of the selectivity tests show that this method is selective, as no other drugs respond at the same time as isoniazid. Based on the validation parameters and the determination of isoniazid level, it was determined that the HPLC method may be used to determine the amount of isoniazid in the 2 FDC dispersible tablet formulation resulting from the dissolution test.

Zitieren

APA

Puspitasari, L., Putri, C. Y., Bahri, S., Sari, P. K. N., Pribadi, F. H., & Nugraha, A. E. (2026). High Performance Liquid Chromatography Validation of Isoniazid Analysis Method in 2 Fixed-Dose Combination Dispersible Tablet. Pharmacon: Jurnal Farmasi Indonesia, 60-68. https://doi.org/10.23917/pharmacon.v23i1.6912

Vancouver

Puspitasari L, Putri CY, Bahri S, Sari PKN, Pribadi FH, Nugraha AE. High Performance Liquid Chromatography Validation of Isoniazid Analysis Method in 2 Fixed-Dose Combination Dispersible Tablet. Pharmacon: Jurnal Farmasi Indonesia. 2026:60-68. doi:10.23917/pharmacon.v23i1.6912

BibTeX
@article{Puspitasari2026,
  author = {Puspitasari, Lia and Putri, Chyntia Yoane and Bahri, Saiful and Sari, Putri Kharisma Novita and Pribadi, Fitrawan Hernuza and Nugraha, Akbar Eka},
  title = {High Performance Liquid Chromatography Validation of Isoniazid Analysis Method in 2 Fixed-Dose Combination Dispersible Tablet},
  journal = {Pharmacon: Jurnal Farmasi Indonesia},
  year = {2026},
  pages = {60--68},
  doi = {10.23917/pharmacon.v23i1.6912}
}
Kostenlos starten →