A Portable Heat-Exchange-Based System for Assessing Digital Vascular Response to Cold
La Medicina del Lavoro · 03.08.2026 · 117 (4) · 19227
DOI: 10.23749/mdl.2026.19227 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift La Medicina del Lavoro, erschienen am 03.08.2026. Verfasst von Carlotta Massotti und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy. Hauptthemen laut MEDLINE: Cold Temperature, Fingers. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Background
Digital vascular assessment is relevant in occupational medicine, but current measurement methods may be complex and poorly portable.
Objective
To validate a portable heat-exchange-based system for assessing cold-induced digital vascular response, using strain-gauge plethysmography as the reference method.
Methods
Twenty healthy volunteers, 10 males and 10 females, underwent five subsequent sessions. Finger blood flow (FBF) was assessed by strain-gauge plethysmography, while simultaneously, fingertip thermal power (TP) was recorded with a portable thermoflowmeter. FBF was measured at baseline, while both FBF and TP were measured during application of 1-N contact force alone and during 1-N force combined with local cooling at 10 °C. The relationship between TP and FBF, after adjustment for covariates (age, sex, body mass index (BMI), and room temperature), was evaluated in the cooled condition using a linear mixed model including fixed and random effects.
Results
Local cooling induced a significant vascular response, with FBF decreasing from 1.23 to 0.98 ml/100 ml/s (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, Politecnico di Milano, Milan, Italy.
- Clinical Unit of Occupational Medicine, Department of Medical Sciences, University of Trieste, U.C.O. di Medicina del Lavoro, Trieste, Italy.
- Department of Occupational and Environmental Medicine, Epidemiology and Hygiene, National Institute for Insurance Against Accidents at Work (INAIL), Monte Porzio Catone, Rome, Italy.
Zitieren
APA
Massotti, C., Bertoli, P., Mauro, M., Tarabini, M., Tirabasso, A., & Bovenzi, M. (2026). A Portable Heat-Exchange-Based System for Assessing Digital Vascular Response to Cold. La Medicina del Lavoro, 117(4), 19227. https://doi.org/10.23749/mdl.2026.19227
Vancouver
Massotti C, Bertoli P, Mauro M, Tarabini M, Tirabasso A, Bovenzi M. A Portable Heat-Exchange-Based System for Assessing Digital Vascular Response to Cold. La Medicina del Lavoro. 2026;117(4):19227. doi:10.23749/mdl.2026.19227
BibTeX
@article{Massotti2026,
author = {Massotti, Carlotta and Bertoli, Paolo and Mauro, Marcella and Tarabini, Marco and Tirabasso, Angelo and Bovenzi, Massimo},
title = {A Portable Heat-Exchange-Based System for Assessing Digital Vascular Response to Cold},
journal = {La Medicina del Lavoro},
year = {2026},
volume = {117},
number = {4},
pages = {19227},
doi = {10.23749/mdl.2026.19227}
}