EUVIMEDEUVIMED entdecken
Übersichtsarbeit

Monitor Alarm Fatigue : An Integrative Review

Maria Cvach

Biomedical Instrumentation & Technology · 2012-07 · 46 (4) · 268-277

DOI: 10.2345/0899-8205-46.4.268 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Biomedical Instrumentation & Technology, 2012-07. Verfasst von Maria Cvach. Beteiligte Einrichtung: The Johns Hopkins Hospital, Baltimore, MD, USA. mcvach@jhmi.edu. Hauptthemen laut MEDLINE: Attention, Attitude of Health Personnel, Clinical Alarms, Man-Machine Systems. Die Arbeit wurde bisher 579-mal zitiert (Crossref) und nennt 64 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Alarm fatigue is a national problem and the number one medical device technology hazard in 2012. The problem of alarm desensitization is multifaceted and related to a high false alarm rate, poor positive predictive value, lack of alarm standardization, and the number of alarming medical devices in hospitals today. This integrative review synthesizes research and non-research findings published between 1/1/2000 and 10/1/2011 using The Johns Hopkins Nursing Evidence-Based Practice model. Seventy-two articles were included. Research evidence was organized into five main themes: excessive alarms and effects on staff; nurse's response to alarms; alarm sounds and audibility; technology to reduce false alarms; and alarm notification systems. Non-research evidence was divided into two main themes: strategies to reduce alarm desensitization, and alarm priority and notification systems. Evidence-based practice recommendations and gaps in research are summarized.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AttentionAttitude of Health PersonnelClinical AlarmsMan-Machine SystemsFatigueHumansMedical ErrorsNoiseSafety ManagementUnited States

Autor:innen und Institutionen

  • The Johns Hopkins Hospital, Baltimore, MD, USA. mcvach@jhmi.edu

Zitieren

APA

Cvach, M. (2012). Monitor Alarm Fatigue : An Integrative Review. Biomedical Instrumentation & Technology, 46(4), 268-277. https://doi.org/10.2345/0899-8205-46.4.268

Vancouver

Cvach M. Monitor Alarm Fatigue : An Integrative Review. Biomedical Instrumentation & Technology. 2012;46(4):268-277. doi:10.2345/0899-8205-46.4.268