EUVIMEDEUVIMED entdecken
Crossref

Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines

S Rojas-Rueda, A I Hernandez, S Abuhammoud, C A Jurado, C-C Fu, N C Lawson

Operative Dentistry · 2025

DOI: 10.2341/24-073-l ↗

Kurz gefasst

Fachartikel in der Zeitschrift Operative Dentistry, 2025. Verfasst von S Rojas-Rueda und 5 weiteren Autor:innen. Beteiligte Einrichtung: Silvia Rojas-Rueda, DDS, Master of Science in Dental Biomaterials resident, University of Alabama at Birmingham School of Dentistry, Birmingham, AL, …. Hauptthemen laut MEDLINE: Dental Veneers, Crowns, Computer-Aided Design, Dental Porcelain. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 40 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

This study aimed to assess the fracture resistance of chairside computer assisted design and computer assisted manufacturing (CAD-CAM) lithium disilicate partial and full-coverage crowns and veneers for maxillary canines. Methods and Materials: Forty-eight restorations for maxillary right canines (12 per group) were designed as follows: (1) partial crown with finish line in the upper middle third; (2) partial crown with finish line in the lower middle third; (3) traditional labial veneer; and (4) traditional full-coverage crown. Restorations were fabricated out of lithium disilicate (Amber Mill, Hassbio) using a chairside CAD-CAM system (Cerec Dentsply Sirona). Partial and full crowns and veneers were treated with a primer system (Monobond Plus, Ivoclar Vivadent) and cemented using dual-cure resin cement (Variolink Esthetic, Ivoclar Vivadent) and cemented to printed resin dies. Subsequently, the restorations were subjected to 10,000 thermocycles between 5°C and 55°C with a dwell time of 30 seconds. The restorations were then loaded axially on the incisal edge in compression to fracture with a flat indenter.

Results

Full-coverage crowns displayed the highest fracture resistance (809±28.57 N) followed by partial crowns with finish line in lower third (649±21.74 N) and crowns with finish line in upper third (421±17.46 N). Veneers displayed the lowest fracture resistance values (259±15.69 N).

Conclusions

The fracture resistance of partial and full-coverage crowns and veneers was significantly influenced by the design. Full coverage crowns displayed the highest fracture resistance and partial crowns showed higher fracture resistance than traditional veneers.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental VeneersCrownsComputer-Aided DesignDental PorcelainCuspidDental Restoration FailureHumansMaxillaDental Stress AnalysisDental Prosthesis DesignResin CementsMaterials TestingTooth Fractures

Substanzen

lithia disilicateDental PorcelainResin Cements

Autor:innen und Institutionen

  • Silvia Rojas-Rueda, DDS, Master of Science in Dental Biomaterials resident, University of Alabama at Birmingham School of Dentistry, Birmingham, AL, USA.
  • Alfredo I. Hernandez, DDS, MS, associate professor, Division of Prosthodontics, ATSU Arizona School of Dentistry & Oral Health, Mesa, AZ, USA.
  • Salahaldeen Abuhammoud, DDS, MS, assistant professor, Department of Prosthodontics, University of Iowa College of Dentistry and Dental Clinics, Iowa City, USA.
  • *Carlos A. Jurado, DDS, MS, director, Division of Operative Dentistry and associate professor, Department of General Dentistry, University of Tennessee Health Science Center College of Dentistry, Memphis, TN, USA.
  • Chin-Chuan Fu, DDS, MS, chair and associate professor, Department of Restorative Sciences, University of Alabama at Birmingham School of Dentistry.
  • Nathaniel C Lawson, DDS, PhD, director of Master of Science in Dental Biomaterials program and associate professor, Department of Clinical and Community Sciences, University of Alabama at Birmingham School of Dentistry,…

Zitieren

APA

Rojas-Rueda, S., Hernandez, A. I., Abuhammoud, S., Jurado, C. A., Fu, C. C., & Lawson, N. C. (2025). Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines. Operative Dentistry. https://doi.org/10.2341/24-073-l

Vancouver

Rojas-Rueda S, Hernandez AI, Abuhammoud S, Jurado CA, Fu CC, Lawson NC. Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines. Operative Dentistry. 2025. doi:10.2341/24-073-l

BibTeX
@article{RojasRueda2025,
  author = {Rojas-Rueda, S and Hernandez, A I and Abuhammoud, S and Jurado, C A and Fu, C-C and Lawson, N C},
  title = {Fracture Resistance of Chairside CAD/CAM Lithium Disilicate Partial and Full Coverage Crowns and Veneers for Maxillary Canines},
  journal = {Operative Dentistry},
  year = {2025},
  doi = {10.2341/24-073-l}
}
Kostenlos starten →