EUVIMEDEUVIMED entdecken
Crossref

Accuracy of Color Determination by Intraoral Scanners in Bleached and Unbleached Teeth: A Clinical Study

B D Kaya, P Yilmaz Atali, E Kahramanoĝlu, B Tarçin

Operative Dentistry · 2024

DOI: 10.2341/24-014-c ↗

Kurz gefasst

Fachartikel in der Zeitschrift Operative Dentistry, 2024. Verfasst von B D Kaya und 3 weiteren Autor:innen. Beteiligte Einrichtung: *Bengü Dogü Kaya, DDS, Marmara University, Faculty of Dentistry, Department of Restorative Dentistry, Istanbul, Turkey. Hauptthemen laut MEDLINE: Color, Spectrophotometry, Tooth Bleaching. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 50 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

This clinical study aimed to evaluate the color measurement ability of intraoral scanners (Trios 3, (3Shape, Copenhagen, Denmark) and Cerec Omnicam, (Dentsply Sirona, Charlotte, NC, USA) in comparison to VITA Classical and VITA 3D-Master shades obtained by a spectrophotometer (Easyshade V, VITA, Zahnfabrik, Bad Säckingen, Germany).

Methods

Four hundred eighty teeth from thirty patients were included in the study. Fifteen patients had never undergone bleaching, and the other fifteen had undergone professional bleaching within the last 6 months. VITA Classical and VITA 3D Master shades were determined using Trios 3 (T3), Cerec Omnicam (CO), and EasyShade V from cervical, middle, and incisal/occlusal areas of maxillary and mandibular central and lateral incisors, canines, and first premolars. Color accuracy rates (cAR) were assessed by categorizing the color data according to the Munsell color system for bleached and unbleached teeth, maxillary and mandibular, and teeth arranged from anterior to posterior in each quadrant. McNemar, Mann-Whitney U, and Wilcoxon tests and Point Biserial Correlation Analysis were used for statistical analysis (significance level α=0.050).

Results

The bleached teeth had a significantly higher cAR for T3 in VITA 3D Master and VITA Classical guides ( p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ColorSpectrophotometryTooth BleachingHumansFemaleMaleAdultToothColorimetry

Autor:innen und Institutionen

  • *Bengü Dogü Kaya, DDS, Marmara University, Faculty of Dentistry, Department of Restorative Dentistry, Istanbul, Turkey.
  • Pinar Yilmaz Atali, PhD, Marmara University, Faculty of Dentistry, Department of Restorative Dentistry, Istanbul, Turkey.
  • Erkut Kahramanoĝlu, PhD, Marmara University, Faculty of Dentistry, Department of Prosthodontics, Istanbul, Turkey.
  • Bilge Tarçin, PhD, Marmara University, Faculty of Dentistry, Department of Restorative Dentistry, Istanbul, Turkey.

Zitieren

APA

Kaya, B. D., Atali, P. Y., Kahramanoĝlu, E., & Tarçin, B. (2024). Accuracy of Color Determination by Intraoral Scanners in Bleached and Unbleached Teeth: A Clinical Study. Operative Dentistry. https://doi.org/10.2341/24-014-c

Vancouver

Kaya BD, Atali PY, Kahramanoĝlu E, Tarçin B. Accuracy of Color Determination by Intraoral Scanners in Bleached and Unbleached Teeth: A Clinical Study. Operative Dentistry. 2024. doi:10.2341/24-014-c

BibTeX
@article{Kaya2024,
  author = {Kaya, B D and Atali, P Yilmaz and Kahramanoĝlu, E and Tarçin, B},
  title = {Accuracy of Color Determination by Intraoral Scanners in Bleached and Unbleached Teeth: A Clinical Study},
  journal = {Operative Dentistry},
  year = {2024},
  doi = {10.2341/24-014-c}
}
Kostenlos starten →