EUVIMEDEUVIMED entdecken
Crossref

Bonding Protocols to Reverse the Bond Strength of a Universal Adhesive to Hemostatic Agent-contaminated Dentin

J Pratabsingha, S Noppawong, C Thamsoonthorn, W Vichathai, P Saikaew

Operative Dentistry · 2023-07 · 48 (4) · 447-456

DOI: 10.2341/22-091-l ↗

Kurz gefasst

Fachartikel in der Zeitschrift Operative Dentistry, 2023-07. Verfasst von J Pratabsingha und 4 weiteren Autor:innen. Beteiligte Einrichtung: Jaikaew Pratabsingha, DDS, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand. Hauptthemen laut MEDLINE: Dental Bonding, Dentin-Bonding Agents, Hemostatics. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To evaluate the effect of different bonding protocols on the microtensile bond strength (μTBS) of a universal adhesive to dentin contaminated with a hemostatic agent. Methods and Materials: Ninety-five extracted premolars were used in this study. For the μTBS test, 80 teeth were cut to expose mid-coronal dentin and randomly divided into two groups (uncontaminated dentin and hemostatic agent-contaminated dentin). Each group was further divided into five subgroups (n=8/group): 1) SE: no additional treatment, 2) ER: etching with 32% phosphoric acid, 3) CHX: rinsing with 0.2% chlorhexidine, 4) EDTA: rinsing with 17% EDTA, and 5) T40: application of universal adhesive for 40 seconds. A universal adhesive was applied followed by resin composite build-up. μTBS test was performed after 24 hours of water storage. Two-way analysis of variance (ANOVA) was calculated followed by the Duncan testing (α=0.05). The failure mode was analyzed using light microscopy. Additional teeth were prepared for energy-dispersive X-ray (EDX) analysis (n=1/group) and resin-dentin interface observation (n=2/group) using scanning electron microscopy.

Results

Adverse effects of hemostatic agent contamination on the bonding performance of a universal adhesive was found in the SE, CHX, and T40 groups ( p

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Dental BondingDentin-Bonding AgentsHemostaticsComposite ResinsDental CementsDentinEdetic AcidMaterials TestingResin CementsTensile StrengthRandom Allocation

Substanzen

Composite ResinsDental CementsDentin-Bonding AgentsEdetic AcidHemostaticsResin Cements

Autor:innen und Institutionen

  • Jaikaew Pratabsingha, DDS, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand.
  • Sawaphon Noppawong, DDS, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand.
  • Chanida Thamsoonthorn, DDS, MSD, Grad Dip in Clin Sc, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand.
  • Weeranun Vichathai, DDS, Grad Dip in Clin Sc, Dip Thai Board of General Dentistry, Institute of Dentistry, Department of Medical Services, Nonthaburi, Thailand.
  • *Pipop Saikaew, DDS, MSc, PhD, assistant professor, Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.

Zitieren

APA

Pratabsingha, J., Noppawong, S., Thamsoonthorn, C., Vichathai, W., & Saikaew, P. (2023). Bonding Protocols to Reverse the Bond Strength of a Universal Adhesive to Hemostatic Agent-contaminated Dentin. Operative Dentistry, 48(4), 447-456. https://doi.org/10.2341/22-091-l

Vancouver

Pratabsingha J, Noppawong S, Thamsoonthorn C, Vichathai W, Saikaew P. Bonding Protocols to Reverse the Bond Strength of a Universal Adhesive to Hemostatic Agent-contaminated Dentin. Operative Dentistry. 2023;48(4):447-456. doi:10.2341/22-091-l

BibTeX
@article{Pratabsingha2023,
  author = {Pratabsingha, J and Noppawong, S and Thamsoonthorn, C and Vichathai, W and Saikaew, P},
  title = {Bonding Protocols to Reverse the Bond Strength of a Universal Adhesive to Hemostatic Agent-contaminated Dentin},
  journal = {Operative Dentistry},
  year = {2023},
  volume = {48},
  number = {4},
  pages = {447--456},
  doi = {10.2341/22-091-l}
}
Kostenlos starten →